{"id":-2048906445,"chronicle_id":"0900c8af85e02b33","project_document_id":"0800c8af851dd419","fk_document_type":4,"document_type":"diag:servinfosub","vcc_number":"VCC-424527-3","nevis_id":"0900c8af85e02b33","path":"VCC-424527-3\\0900c8af85e02b33_ru-RU.xml","title":"Поиск неисправности","xml_filename":"0900c8af85e02b33_ru-RU.xml","description_raw":"<?xml version=\"1.0\" encoding=\"utf-8\"?><servinfosub docno=\"VCC-424527\" id=\"nev16449288n1\" xml:lang=\"ru-RU\" IE-ID=\"ru-RU0900c8af85e02b33\"><title><phrase category=\"Title\" id=\"nev16449288n2\" phrase-urn=\"urn:x-nevis:phrase:0800c8af81eb9a59\">Поиск неисправности</phrase></title><diagnostic id=\"nev16449288n3\" j2008use=\"1\" layout=\"0\" paperuse=\"1\" screenuse=\"1\" type=\"test\"><testgrp id=\"nev16449288n4\" j2008use=\"1\" paperuse=\"0\" resumable=\"1\" screenuse=\"1\" testgrp-id=\"node0\" x=\"120\" y=\"100\" IE-ID=\"ru-RU0900c8af85e02b33_nev16449288n4\"><title id=\"nev16449288n5\"><phrase category=\"Title\" id=\"nev16449288n6\" phrase-urn=\"urn:x-nevis:phrase:0800c8af81eb9b67\">Проверка связи</phrase></title><node id=\"nev16449288n7\"><test1 id=\"nev16449288n8\"><test2 id=\"nev16449288n9\"><para id=\"nev16449288n10\"><ptxt id=\"nev16449289n1\"><phrase category=\"Faulttracing\" id=\"nev16449289n2\" phrase-urn=\"urn:x-nevis:phrase:0800c8af851c6037\">Модули управления в локальной сети датчик-CAN могут обнаружить короткое замыкание, когда они посылают сигналы.</phrase><phrase category=\"Faulttracing\" id=\"nev16449289n3\" phrase-urn=\"urn:x-nevis:phrase:0800c8af851c6050\">Выполните поиск неисправности для кабелей на наличие короткого замыкания.</phrase></ptxt></para><para id=\"nev16449289n4\"><ptxt id=\"nev16449289n5\"><phrase category=\"Faulttracing\" id=\"nev16449289n6\" phrase-urn=\"urn:x-nevis:phrase:0800c8af845254de\">Проверьте коммуникацию CAN между модулем дополнительной системы удерживания (SRS), модулем предельной скорости (CVM) и датчиком веса сидящего (OWS) (только рынок США/Канады).</phrase></ptxt></para><para id=\"nev16449289n7\"><ptxt id=\"nev16449289n8\"><phrase category=\"Faulttracing\" id=\"nev16449289n9\" phrase-urn=\"urn:x-nevis:phrase:0800c8af825ad7b2\">Если неисправность не была найдена:</phrase><phrase category=\"Faulttracing\" id=\"nev16449289n10\" phrase-urn=\"urn:x-nevis:phrase:0800c8af84524e7a\">Выполните поиск неисправности в модуле предельной скорости (CVM).</phrase></ptxt></para><para id=\"nev16449290n1\"><title id=\"nev16449290n2\"><phrase category=\"Title\" id=\"nev16449290n3\" phrase-urn=\"urn:x-nevis:phrase:0800c8af81ea4c43\">Информация по поиску неисправности</phrase></title><ptxt id=\"nev16449290n4\"><phrase category=\"Faulttracing\" id=\"nev16449290n5\" phrase-urn=\"urn:x-nevis:phrase:0800c8af851c62a5\">Ниже представлена подборка того, какие коды неисправности могут устанавливаться в локальной сети датчик-CAN (с учетом будущих изменений/обновлений).</phrase><phrase category=\"Faulttracing\" id=\"nev16449290n6\" phrase-urn=\"urn:x-nevis:phrase:0800c8af851c62aa\">В таблице показано, где в локальной сети датчик-CAN могут быть неисправности.</phrase></ptxt></para><table colsep=\"1\" frame=\"all\" id=\"nev16449290n7\" orient=\"land\" pgwide=\"1\" rowsep=\"1\" shortentry=\"0\" tabstyle=\"BH\" tocentry=\"1\"><title id=\"nev16449290n8\"><phrase category=\"Title\" id=\"nev16449290n9\" phrase-urn=\"urn:x-nevis:phrase:0800c8af851c62b0\">Таблица кодов неисправности для локальной сети датчик-CAN</phrase></title><tgroup align=\"center\" char=\"10\" charoff=\"10\" cols=\"8\" colsep=\"1\" id=\"nev16449290n10\" rowsep=\"1\" tgroupstyle=\"0\"><tbody id=\"nev16449291n1\"><row id=\"nev16449291n2\" rowsep=\"1\" valign=\"top\"><entry id=\"nev16449291n3\"><ptxt id=\"nev16449291n4\"><phrase category=\"Faulttracing\" id=\"nev16449291n5\" phrase-urn=\"urn:x-nevis:phrase:0800c8af851d926a\">Код неисправности в модуле управления</phrase></ptxt></entry><entry id=\"nev16449291n6\"><ptxt id=\"nev16449291n7\"><phrase category=\"Title\" id=\"nev16449291n8\" phrase-urn=\"urn:x-nevis:phrase:0800c8af851d926e\">Короткое замыкание, обрыв, внутренняя неисправность, поврежденный модуль управления (\"bus-off\")</phrase></ptxt></entry><entry id=\"nev16449291n9\"><ptxt id=\"nev16449291n10\"><phrase category=\"Title\" id=\"nev16449292n1\" phrase-urn=\"urn:x-nevis:phrase:0800c8af851d9271\">Ошибка ID конфигурации</phrase></ptxt></entry><entry id=\"nev16449292n2\"><ptxt id=\"nev16449292n3\"><phrase category=\"Title\" id=\"nev16449292n4\" phrase-urn=\"urn:x-nevis:phrase:0800c8af851d9333\">SRS, сигнал отсутствует</phrase></ptxt></entry><entry id=\"nev16449292n5\"><ptxt id=\"nev16449292n6\"><phrase category=\"Title\" id=\"nev16449292n7\" phrase-urn=\"urn:x-nevis:phrase:0800c8af851d9334\">BCM, сигнал отсутствует</phrase></ptxt></entry><entry id=\"nev16449292n8\"><ptxt id=\"nev16449292n9\"><phrase category=\"Title\" id=\"nev16449292n10\" phrase-urn=\"urn:x-nevis:phrase:0800c8af851d934b\">FSM, сигнал отсутствует</phrase></ptxt></entry><entry id=\"nev16449293n1\"><ptxt id=\"nev16449293n2\"><phrase category=\"Title\" id=\"nev16449293n3\" phrase-urn=\"urn:x-nevis:phrase:0800c8af851d9338\">CVM, сигнал отсутствует</phrase></ptxt></entry><entry id=\"nev16449293n4\"><ptxt id=\"nev16449293n5\"><phrase category=\"Title\" id=\"nev16449293n6\" phrase-urn=\"urn:x-nevis:phrase:0800c8af851d9339\">OWS, сигнал отсутствует</phrase></ptxt></entry></row><row id=\"nev16449293n7\" rowsep=\"1\" valign=\"middle\"><entry id=\"nev16449293n8\"><ptxt id=\"nev16449293n9\"><phrase category=\"Title\" id=\"nev16449293n10\" phrase-urn=\"urn:x-nevis:phrase:0800c8af851d935f\">SRS</phrase></ptxt></entry><entry id=\"nev16449294n1\"><ptxt id=\"nev16449294n2\"><phrase category=\"Title\" id=\"nev16449294n3\" phrase-urn=\"urn:x-nevis:phrase:0800c8af851d9360\">U002800</phrase></ptxt></entry><entry id=\"nev16449294n4\"><ptxt id=\"nev16449294n5\"><phrase category=\"Title\" id=\"nev16449294n6\" phrase-urn=\"urn:x-nevis:phrase:0800c8af851d9362\">-</phrase></ptxt></entry><entry id=\"nev16449294n7\"><ptxt id=\"nev16449294n8\"><phrase category=\"Title\" id=\"nev16449294n9\" phrase-urn=\"urn:x-nevis:phrase:0800c8af851d9362\">-</phrase></ptxt></entry><entry id=\"nev16449294n10\"><ptxt id=\"nev16449295n1\"><phrase category=\"Title\" id=\"nev16449295n2\" phrase-urn=\"urn:x-nevis:phrase:0800c8af851d9362\">-</phrase></ptxt></entry><entry id=\"nev16449295n3\"><ptxt id=\"nev16449295n4\"><phrase category=\"Title\" id=\"nev16449295n5\" phrase-urn=\"urn:x-nevis:phrase:0800c8af851d9362\">-</phrase></ptxt></entry><entry id=\"nev16449295n6\"><ptxt id=\"nev16449295n7\"><phrase category=\"Title\" id=\"nev16449295n8\" phrase-urn=\"urn:x-nevis:phrase:0800c8af851d9363\">U023500</phrase></ptxt></entry><entry id=\"nev16449295n9\"><ptxt id=\"nev16449295n10\"><phrase category=\"Title\" id=\"nev16449296n1\" phrase-urn=\"urn:x-nevis:phrase:0800c8af851d9365\">U015400</phrase></ptxt></entry></row><row id=\"nev16449296n2\" rowsep=\"1\" valign=\"middle\"><entry id=\"nev16449296n3\"><ptxt id=\"nev16449296n4\"><phrase category=\"Title\" id=\"nev16449296n5\" phrase-urn=\"urn:x-nevis:phrase:0800c8af851d9375\">Модуль управления тормозами</phrase></ptxt></entry><entry id=\"nev16449296n6\"><ptxt id=\"nev16449296n7\"><phrase category=\"Title\" id=\"nev16449296n8\" phrase-urn=\"urn:x-nevis:phrase:0800c8af851d936b\">U002888</phrase></ptxt></entry><entry id=\"nev16449296n9\"><ptxt id=\"nev16449296n10\"><phrase category=\"Title\" id=\"nev16449297n1\" phrase-urn=\"urn:x-nevis:phrase:0800c8af851d936d\">U002855</phrase></ptxt></entry><entry id=\"nev16449297n2\"><ptxt id=\"nev16449297n3\"><phrase category=\"Title\" id=\"nev16449297n4\" phrase-urn=\"urn:x-nevis:phrase:0800c8af851d936e\">U015100</phrase></ptxt></entry><entry id=\"nev16449297n5\"><ptxt id=\"nev16449297n6\"><phrase category=\"Title\" id=\"nev16449297n7\" phrase-urn=\"urn:x-nevis:phrase:0800c8af851d9362\">-</phrase></ptxt></entry><entry id=\"nev16449297n8\"><ptxt id=\"nev16449297n9\"><phrase category=\"Title\" id=\"nev16449297n10\" phrase-urn=\"urn:x-nevis:phrase:0800c8af851d9373\">U010400</phrase></ptxt></entry><entry id=\"nev16449298n1\"><ptxt id=\"nev16449298n2\"><phrase category=\"Title\" id=\"nev16449298n3\" phrase-urn=\"urn:x-nevis:phrase:0800c8af851d9363\">U023500</phrase></ptxt></entry><entry id=\"nev16449298n4\"><ptxt id=\"nev16449298n5\"><phrase category=\"Title\" id=\"nev16449298n6\" phrase-urn=\"urn:x-nevis:phrase:0800c8af851d9362\">-</phrase></ptxt></entry></row><row id=\"nev16449298n7\" rowsep=\"1\" valign=\"middle\"><entry id=\"nev16449298n8\"><ptxt id=\"nev16449298n9\"><phrase category=\"Title\" id=\"nev16449298n10\" phrase-urn=\"urn:x-nevis:phrase:0800c8af851d9377\">FSM</phrase></ptxt></entry><entry id=\"nev16449299n1\"><ptxt id=\"nev16449299n2\"><phrase category=\"Title\" id=\"nev16449299n3\" phrase-urn=\"urn:x-nevis:phrase:0800c8af851d936b\">U002888</phrase></ptxt></entry><entry id=\"nev16449299n4\"><ptxt id=\"nev16449299n5\"><phrase category=\"Title\" id=\"nev16449299n6\" phrase-urn=\"urn:x-nevis:phrase:0800c8af851d936d\">U002855</phrase></ptxt></entry><entry id=\"nev16449299n7\"><ptxt id=\"nev16449299n8\"><phrase category=\"Title\" id=\"nev16449299n9\" phrase-urn=\"urn:x-nevis:phrase:0800c8af851d936e\">U015100</phrase></ptxt></entry><entry id=\"nev16449299n10\"><ptxt id=\"nev16449300n1\"><phrase category=\"Title\" id=\"nev16449300n2\" phrase-urn=\"urn:x-nevis:phrase:0800c8af851d9362\">-</phrase></ptxt></entry><entry id=\"nev16449300n3\"><ptxt id=\"nev16449300n4\"><phrase category=\"Title\" id=\"nev16449300n5\" phrase-urn=\"urn:x-nevis:phrase:0800c8af851d9362\">-</phrase></ptxt></entry><entry id=\"nev16449300n6\"><ptxt id=\"nev16449300n7\"><phrase category=\"Title\" id=\"nev16449300n8\" phrase-urn=\"urn:x-nevis:phrase:0800c8af851d9362\">-</phrase></ptxt></entry><entry id=\"nev16449300n9\"><ptxt id=\"nev16449300n10\"><phrase category=\"Title\" id=\"nev16449301n1\" phrase-urn=\"urn:x-nevis:phrase:0800c8af851d9362\">-</phrase></ptxt></entry></row><row id=\"nev16449301n2\" rowsep=\"1\" valign=\"middle\"><entry id=\"nev16449301n3\"><ptxt id=\"nev16449301n4\"><phrase category=\"Title\" id=\"nev16449301n5\" phrase-urn=\"urn:x-nevis:phrase:0800c8af851d9379\">CVM</phrase></ptxt></entry><entry id=\"nev16449301n6\"><ptxt id=\"nev16449301n7\"><phrase category=\"Title\" id=\"nev16449301n8\" phrase-urn=\"urn:x-nevis:phrase:0800c8af851d9360\">U002800</phrase></ptxt></entry><entry id=\"nev16449301n9\"><ptxt id=\"nev16449301n10\"><phrase category=\"Title\" id=\"nev16449302n1\" phrase-urn=\"urn:x-nevis:phrase:0800c8af851d937a\">U03004A</phrase></ptxt></entry><entry id=\"nev16449302n2\"><ptxt id=\"nev16449302n3\"><phrase category=\"Title\" id=\"nev16449302n4\" phrase-urn=\"urn:x-nevis:phrase:0800c8af851d9362\">-</phrase></ptxt></entry><entry id=\"nev16449302n5\"><ptxt id=\"nev16449302n6\"><phrase category=\"Title\" id=\"nev16449302n7\" phrase-urn=\"urn:x-nevis:phrase:0800c8af851d9362\">-</phrase></ptxt></entry><entry id=\"nev16449302n8\"><ptxt id=\"nev16449302n9\"><phrase category=\"Title\" id=\"nev16449302n10\" phrase-urn=\"urn:x-nevis:phrase:0800c8af851d9362\">-</phrase></ptxt></entry><entry id=\"nev16449303n1\"><ptxt id=\"nev16449303n2\"><phrase category=\"Title\" id=\"nev16449303n3\" phrase-urn=\"urn:x-nevis:phrase:0800c8af851d9362\">-</phrase></ptxt></entry><entry id=\"nev16449303n4\"><ptxt id=\"nev16449303n5\"><phrase category=\"Title\" id=\"nev16449303n6\" phrase-urn=\"urn:x-nevis:phrase:0800c8af851d9362\">-</phrase></ptxt></entry></row></tbody></tgroup></table><note id=\"nev16449303n7\"><ptxt id=\"nev16449303n8\"><phrase category=\"Faulttracing\" id=\"nev16449303n9\" phrase-urn=\"urn:x-nevis:phrase:0800c8af82d740f9\">Более подробная информация приведена в разделе <emph etype=\"bold\">Устройство и коммуникация</emph>.</phrase></ptxt></note><para id=\"nev16449303n10\"><ptxt id=\"nev16449304n1\"><phrase category=\"Faulttracing\" id=\"nev16449304n2\" phrase-urn=\"urn:x-nevis:phrase:0800c8af81eb9478\">Выполните необходимый ремонт.</phrase></ptxt></para><list1 id=\"nev16449304n3\"><title id=\"nev16449304n4\"><phrase category=\"Title\" id=\"nev16449304n5\" phrase-urn=\"urn:x-nevis:phrase:0800c8af81ea4cd6\">Другая информация</phrase></title><item id=\"nev16449304n6\"><ptxt id=\"nev16449304n7\"><xref id=\"nev19320182n100\"><ref id=\"nev16449304n9\"><href title=\"VCC-462032-1, Общая информация о поиске неисправности в сети CAN\">ru-RU0900c8af85dea93a#nev19307028n1</href></ref></xref></ptxt></item><item id=\"nev16449304n10\"><ptxt id=\"nev16449305n1\"><xref id=\"nev16449305n2\"><ref id=\"nev16449305n3\"><href title=\"VCC-285354-1, Описание зафиксированных значений\">ru-RU0900c8af8346c120#nev11400823n1</href></ref></xref></ptxt></item><item id=\"nev16449305n4\"><ptxt id=\"nev16449305n5\"><xref id=\"nev16449305n6\"><ref id=\"nev16449305n7\"><href title=\"VCC-167215-1, Beskrivning av statusidentifierare\">ru-RU0900c8af823e5d0c#KC09023161</href></ref></xref></ptxt></item><item id=\"nev16449305n8\"><ptxt id=\"nev16449305n9\"><xref id=\"nev16449305n10\"><ref id=\"nev16449306n1\"><href title=\"VCC-167216-1, Beskrivning av räknare\">ru-RU0900c8af823e5d0e#KC09047625</href></ref></xref></ptxt></item><item id=\"nev16449306n2\"><ptxt id=\"nev16449306n3\"><xref id=\"nev16449306n4\"><ref id=\"nev16449306n5\"><href title=\"VCC-285286-1, Описание параметров\">ru-RU0900c8af8504d3df#nev11394024n1</href></ref></xref></ptxt></item><item id=\"nev16449306n6\"><ptxt id=\"nev16449306n7\"><xref id=\"nev18163452n100\"><ref id=\"nev16449306n9\"><href title=\"VCC-407473-1, Расположение компонентов\">ru-RU0900c8af84c8c4fe#nev15229619n1</href></ref></xref></ptxt></item><item id=\"nev16449306n10\"><ptxt id=\"nev16449307n1\"><xref id=\"nev18163452n98\"><ref id=\"nev16449307n3\"><href title=\"VCC-407467-1, Характеристики сигналов\">ru-RU0900c8af84c8c49c#nev15229205n1</href></ref></xref></ptxt></item><item id=\"nev16449307n4\"><ptxt id=\"nev16449307n5\"><xref id=\"nev16449307n6\"><ref id=\"nev16449307n7\"><href title=\"VCC-123664-1, Проверка проводки и выводов\">ru-RU0900c8af8426e544#KC01108712</href></ref></xref></ptxt></item><item id=\"nev16449307n8\"><ptxt id=\"nev16449307n9\"><xref id=\"nev16449307n10\"><ref id=\"nev16449308n1\"><href title=\"VCC-285160-3, Подсоединение измерительного блока\">ru-RU0900c8af8506fcdc#nev11390876n1</href></ref></xref></ptxt></item></list1><grate><graphic id=\"nev16449308n2\"><href title=\"IMG-341203\">0900c8af84ea1634_80_60.gif</href></graphic></grate></test2></test1><question id=\"nev16449308n3\"><phrase category=\"Question\" id=\"nev16449308n4\" phrase-urn=\"urn:x-nevis:phrase:0800c8af81eb97f1\">После устранения неисправности выберите \"Продолжить\" (Continue).</phrase></question><resact-grp id=\"nev16449308n5\"><result button=\"cont\" comp=\"button\" highlight=\"0\" id=\"nev16449308n6\"></result><action id=\"nev16449308n7\" j2008use=\"1\" paperuse=\"0\" screenuse=\"1\"><return id=\"nev16449308n8\" value=\"DONE\"></return></action></resact-grp></node></testgrp></diagnostic></servinfosub>","description_plain":"Поиск неисправности\nПроверка связи\nМодули управления в локальной сети датчик-CAN могут обнаружить короткое замыкание, когда они посылают сигналы.Выполните поиск неисправности для кабелей на наличие короткого замыкания.\nМодули управления в локальной сети датчик-CAN могут обнаружить короткое замыкание, когда они посылают сигналы.\nВыполните поиск неисправности для кабелей на наличие короткого замыкания.\nПроверьте коммуникацию CAN между модулем дополнительной системы удерживания (SRS), модулем предельной скорости (CVM) и датчиком веса сидящего (OWS) (только рынок США/Канады).\nЕсли неисправность не была найдена:Выполните поиск неисправности в модуле предельной скорости (CVM).\nЕсли неисправность не была найдена:\nВыполните поиск неисправности в модуле предельной скорости (CVM).\nИнформация по поиску неисправностиНиже представлена подборка того, какие коды неисправности могут устанавливаться в локальной сети датчик-CAN (с учетом будущих изменений/обновлений).В таблице показано, где в локальной сети датчик-CAN могут быть неисправности.\nИнформация по поиску неисправности\nНиже представлена подборка того, какие коды неисправности могут устанавливаться в локальной сети датчик-CAN (с учетом будущих изменений/обновлений).В таблице показано, где в локальной сети датчик-CAN могут быть неисправности.\nНиже представлена подборка того, какие коды неисправности могут устанавливаться в локальной сети датчик-CAN (с учетом будущих изменений/обновлений).\nВ таблице показано, где в локальной сети датчик-CAN могут быть неисправности.\nТаблица кодов неисправности для локальной сети датчик-CAN\nКод неисправности в модуле управления\nКороткое замыкание, обрыв, внутренняя неисправность, поврежденный модуль управления (\"bus-off\")\nОшибка ID конфигурации\nSRS, сигнал отсутствует\nBCM, сигнал отсутствует\nFSM, сигнал отсутствует\nCVM, сигнал отсутствует\nOWS, сигнал отсутствует\nSRS\nU002800\n-\nU023500\nU015400\nМодуль управления тормозами\nU002888\nU002855\nU015100\nU010400\nFSM\nCVM\nU03004A\nБолее подробная информация приведена в разделе Устройство и коммуникация.\nВыполните необходимый ремонт.\nДругая информация\nru-RU0900c8af85dea93a#nev19307028n1\nru-RU0900c8af8346c120#nev11400823n1\nru-RU0900c8af823e5d0c#KC09023161\nru-RU0900c8af823e5d0e#KC09047625\nru-RU0900c8af8504d3df#nev11394024n1\nru-RU0900c8af84c8c4fe#nev15229619n1\nru-RU0900c8af84c8c49c#nev15229205n1\nru-RU0900c8af8426e544#KC01108712\nru-RU0900c8af8506fcdc#nev11390876n1\nПосле устранения неисправности выберите \"Продолжить\" (Continue).","description_markdown":"# Поиск неисправности\n\nПоиск неисправности\n\nПроверка связи\n\nМодули управления в локальной сети датчик-CAN могут обнаружить короткое замыкание, когда они посылают сигналы.Выполните поиск неисправности для кабелей на наличие короткого замыкания.\n\nМодули управления в локальной сети датчик-CAN могут обнаружить короткое замыкание, когда они посылают сигналы.\n\nВыполните поиск неисправности для кабелей на наличие короткого замыкания.\n\nПроверьте коммуникацию CAN между модулем дополнительной системы удерживания (SRS), модулем предельной скорости (CVM) и датчиком веса сидящего (OWS) (только рынок США/Канады).\n\nЕсли неисправность не была найдена:Выполните поиск неисправности в модуле предельной скорости (CVM).\n\nЕсли неисправность не была найдена:\n\nВыполните поиск неисправности в модуле предельной скорости (CVM).\n\nИнформация по поиску неисправностиНиже представлена подборка того, какие коды неисправности могут устанавливаться в локальной сети датчик-CAN (с учетом будущих изменений/обновлений).В таблице показано, где в локальной сети датчик-CAN могут быть неисправности.\n\nИнформация по поиску неисправности\n\nНиже представлена подборка того, какие коды неисправности могут устанавливаться в локальной сети датчик-CAN (с учетом будущих изменений/обновлений).В таблице показано, где в локальной сети датчик-CAN могут быть неисправности.\n\nНиже представлена подборка того, какие коды неисправности могут устанавливаться в локальной сети датчик-CAN (с учетом будущих изменений/обновлений).\n\nВ таблице показано, где в локальной сети датчик-CAN могут быть неисправности.\n\nТаблица кодов неисправности для локальной сети датчик-CAN\n\nКод неисправности в модуле управления\n\nКороткое замыкание, обрыв, внутренняя неисправность, поврежденный модуль управления (\"bus-off\")\n\nОшибка ID конфигурации\n\nSRS, сигнал отсутствует\n\nBCM, сигнал отсутствует\n\nFSM, сигнал отсутствует\n\nCVM, сигнал отсутствует\n\nOWS, сигнал отсутствует\n\nSRS\n\nU002800\n\n-\n\nU023500\n\nU015400\n\nМодуль управления тормозами\n\nU002888\n\nU002855\n\nU015100\n\nU010400\n\nFSM\n\nCVM\n\nU03004A\n\nБолее подробная информация приведена в разделе Устройство и коммуникация.\n\nВыполните необходимый ремонт.\n\nДругая информация\n\nru-RU0900c8af85dea93a#nev19307028n1\n\nru-RU0900c8af8346c120#nev11400823n1\n\nru-RU0900c8af823e5d0c#KC09023161\n\nru-RU0900c8af823e5d0e#KC09047625\n\nru-RU0900c8af8504d3df#nev11394024n1\n\nru-RU0900c8af84c8c4fe#nev15229619n1\n\nru-RU0900c8af84c8c49c#nev15229205n1\n\nru-RU0900c8af8426e544#KC01108712\n\nru-RU0900c8af8506fcdc#nev11390876n1\n\n## Вопрос\n\nПосле устранения неисправности выберите \"Продолжить\" (Continue).","xml_size":3137}