{"id":-2048906565,"chronicle_id":"0900c8af851dd504","project_document_id":"0800c8af851dd503","fk_document_type":4,"document_type":"diag:servinfosub","vcc_number":"VCC-424533-1","nevis_id":"0900c8af85e02abb","path":"VCC-424533-1\\0900c8af85e02abb_ru-RU.xml","title":"Поиск неисправности","xml_filename":"0900c8af85e02abb_ru-RU.xml","description_raw":"<?xml version=\"1.0\" encoding=\"utf-8\"?><servinfosub docno=\"VCC-424533\" id=\"nev16451461n1\" xml:lang=\"ru-RU\" IE-ID=\"ru-RU0900c8af85e02abb\"><title><phrase category=\"Title\" id=\"nev16451461n2\" phrase-urn=\"urn:x-nevis:phrase:0800c8af81eb9a59\">Поиск неисправности</phrase></title><diagnostic id=\"nev16451461n3\" j2008use=\"1\" layout=\"0\" paperuse=\"1\" screenuse=\"1\" type=\"test\"><testgrp id=\"nev16451461n4\" j2008use=\"1\" paperuse=\"0\" resumable=\"1\" screenuse=\"1\" testgrp-id=\"node0\" x=\"120\" y=\"80\" IE-ID=\"ru-RU0900c8af85e02abb_nev16451461n4\"><title id=\"nev16451461n5\"><phrase category=\"Title\" id=\"nev16451461n6\" phrase-urn=\"urn:x-nevis:phrase:0800c8af81eb9b67\">Проверка связи</phrase></title><node id=\"nev16451461n7\"><test1 id=\"nev16451461n8\"><test2 id=\"nev16451461n9\"><para id=\"nev16451461n10\"><ptxt id=\"nev16451462n1\"><phrase category=\"Faulttracing\" id=\"nev16451462n2\" phrase-urn=\"urn:x-nevis:phrase:0800c8af851c6037\">Модули управления в локальной сети датчик-CAN могут обнаружить короткое замыкание, когда они посылают сигналы.</phrase><phrase category=\"Faulttracing\" id=\"nev16451462n3\" phrase-urn=\"urn:x-nevis:phrase:0800c8af851c6050\">Выполните поиск неисправности для кабелей на наличие короткого замыкания.</phrase></ptxt></para><para id=\"nev16451462n4\"><ptxt id=\"nev16451462n5\"><phrase category=\"Faulttracing\" id=\"nev16451462n6\" phrase-urn=\"urn:x-nevis:phrase:0800c8af845254de\">Проверьте коммуникацию CAN между модулем дополнительной системы удерживания (SRS), модулем предельной скорости (CVM) и датчиком веса сидящего (OWS) (только рынок США/Канады).</phrase></ptxt></para><para id=\"nev16451462n7\"><ptxt id=\"nev16451462n8\"><phrase category=\"Faulttracing\" id=\"nev16451462n9\" phrase-urn=\"urn:x-nevis:phrase:0800c8af825ad7b2\">Если неисправность не была найдена:</phrase><phrase category=\"Faulttracing\" id=\"nev16451462n10\" phrase-urn=\"urn:x-nevis:phrase:0800c8af84524e7a\">Выполните поиск неисправности в модуле предельной скорости (CVM).</phrase></ptxt></para><para id=\"nev16451463n1\"><title id=\"nev16451463n2\"><phrase category=\"Title\" id=\"nev16451463n3\" phrase-urn=\"urn:x-nevis:phrase:0800c8af81ea4c43\">Информация по поиску неисправности</phrase></title><ptxt id=\"nev16451463n4\"><phrase category=\"Faulttracing\" id=\"nev16451463n5\" phrase-urn=\"urn:x-nevis:phrase:0800c8af851c62a5\">Ниже представлена подборка того, какие коды неисправности могут устанавливаться в локальной сети датчик-CAN (с учетом будущих изменений/обновлений).</phrase><phrase category=\"Faulttracing\" id=\"nev16451463n6\" phrase-urn=\"urn:x-nevis:phrase:0800c8af851c62aa\">В таблице показано, где в локальной сети датчик-CAN могут быть неисправности.</phrase></ptxt></para><table colsep=\"1\" frame=\"all\" id=\"nev16451463n7\" orient=\"land\" pgwide=\"1\" rowsep=\"1\" shortentry=\"0\" tabstyle=\"BH\" tocentry=\"1\"><title id=\"nev16451463n8\"><phrase category=\"Title\" id=\"nev16451463n9\" phrase-urn=\"urn:x-nevis:phrase:0800c8af851c62b0\">Таблица кодов неисправности для локальной сети датчик-CAN</phrase></title><tgroup align=\"center\" char=\"10\" charoff=\"10\" cols=\"8\" colsep=\"1\" id=\"nev16451463n10\" rowsep=\"1\" tgroupstyle=\"0\"><tbody id=\"nev16451464n1\"><row id=\"nev16451464n2\" rowsep=\"1\" valign=\"top\"><entry id=\"nev16451464n3\"><ptxt id=\"nev16451464n4\"><phrase category=\"Faulttracing\" id=\"nev16451464n5\" phrase-urn=\"urn:x-nevis:phrase:0800c8af851d926a\">Код неисправности в модуле управления</phrase></ptxt></entry><entry id=\"nev16451464n6\"><ptxt id=\"nev16451464n7\"><phrase category=\"Title\" id=\"nev16451464n8\" phrase-urn=\"urn:x-nevis:phrase:0800c8af851d926e\">Короткое замыкание, обрыв, внутренняя неисправность, поврежденный модуль управления (\"bus-off\")</phrase></ptxt></entry><entry id=\"nev16451464n9\"><ptxt id=\"nev16451464n10\"><phrase category=\"Title\" id=\"nev16451465n1\" phrase-urn=\"urn:x-nevis:phrase:0800c8af851d9271\">Ошибка ID конфигурации</phrase></ptxt></entry><entry id=\"nev16451465n2\"><ptxt id=\"nev16451465n3\"><phrase category=\"Title\" id=\"nev16451465n4\" phrase-urn=\"urn:x-nevis:phrase:0800c8af851d9333\">SRS, сигнал отсутствует</phrase></ptxt></entry><entry id=\"nev16451465n5\"><ptxt id=\"nev16451465n6\"><phrase category=\"Title\" id=\"nev16451465n7\" phrase-urn=\"urn:x-nevis:phrase:0800c8af851d9334\">BCM, сигнал отсутствует</phrase></ptxt></entry><entry id=\"nev16451465n8\"><ptxt id=\"nev16451465n9\"><phrase category=\"Title\" id=\"nev16451465n10\" phrase-urn=\"urn:x-nevis:phrase:0800c8af851d934b\">FSM, сигнал отсутствует</phrase></ptxt></entry><entry id=\"nev16451466n1\"><ptxt id=\"nev16451466n2\"><phrase category=\"Title\" id=\"nev16451466n3\" phrase-urn=\"urn:x-nevis:phrase:0800c8af851d9338\">CVM, сигнал отсутствует</phrase></ptxt></entry><entry id=\"nev16451466n4\"><ptxt id=\"nev16451466n5\"><phrase category=\"Title\" id=\"nev16451466n6\" phrase-urn=\"urn:x-nevis:phrase:0800c8af851d9339\">OWS, сигнал отсутствует</phrase></ptxt></entry></row><row id=\"nev16451466n7\" rowsep=\"1\" valign=\"middle\"><entry id=\"nev16451466n8\"><ptxt id=\"nev16451466n9\"><phrase category=\"Title\" id=\"nev16451466n10\" phrase-urn=\"urn:x-nevis:phrase:0800c8af851d935f\">SRS</phrase></ptxt></entry><entry id=\"nev16451467n1\"><ptxt id=\"nev16451467n2\"><phrase category=\"Title\" id=\"nev16451467n3\" phrase-urn=\"urn:x-nevis:phrase:0800c8af851d9360\">U002800</phrase></ptxt></entry><entry id=\"nev16451467n4\"><ptxt id=\"nev16451467n5\"><phrase category=\"Title\" id=\"nev16451467n6\" phrase-urn=\"urn:x-nevis:phrase:0800c8af851d9362\">-</phrase></ptxt></entry><entry id=\"nev16451467n7\"><ptxt id=\"nev16451467n8\"><phrase category=\"Title\" id=\"nev16451467n9\" phrase-urn=\"urn:x-nevis:phrase:0800c8af851d9362\">-</phrase></ptxt></entry><entry id=\"nev16451467n10\"><ptxt id=\"nev16451468n1\"><phrase category=\"Title\" id=\"nev16451468n2\" phrase-urn=\"urn:x-nevis:phrase:0800c8af851d9362\">-</phrase></ptxt></entry><entry id=\"nev16451468n3\"><ptxt id=\"nev16451468n4\"><phrase category=\"Title\" id=\"nev16451468n5\" phrase-urn=\"urn:x-nevis:phrase:0800c8af851d9362\">-</phrase></ptxt></entry><entry id=\"nev16451468n6\"><ptxt id=\"nev16451468n7\"><phrase category=\"Title\" id=\"nev16451468n8\" phrase-urn=\"urn:x-nevis:phrase:0800c8af851d9363\">U023500</phrase></ptxt></entry><entry id=\"nev16451468n9\"><ptxt id=\"nev16451468n10\"><phrase category=\"Title\" id=\"nev16451469n1\" phrase-urn=\"urn:x-nevis:phrase:0800c8af851d9365\">U015400</phrase></ptxt></entry></row><row id=\"nev16451469n2\" rowsep=\"1\" valign=\"middle\"><entry id=\"nev16451469n3\"><ptxt id=\"nev16451469n4\"><phrase category=\"Title\" id=\"nev16451469n5\" phrase-urn=\"urn:x-nevis:phrase:0800c8af851d9375\">Модуль управления тормозами</phrase></ptxt></entry><entry id=\"nev16451469n6\"><ptxt id=\"nev16451469n7\"><phrase category=\"Title\" id=\"nev16451469n8\" phrase-urn=\"urn:x-nevis:phrase:0800c8af851d936b\">U002888</phrase></ptxt></entry><entry id=\"nev16451469n9\"><ptxt id=\"nev16451469n10\"><phrase category=\"Title\" id=\"nev16451470n1\" phrase-urn=\"urn:x-nevis:phrase:0800c8af851d936d\">U002855</phrase></ptxt></entry><entry id=\"nev16451470n2\"><ptxt id=\"nev16451470n3\"><phrase category=\"Title\" id=\"nev16451470n4\" phrase-urn=\"urn:x-nevis:phrase:0800c8af851d936e\">U015100</phrase></ptxt></entry><entry id=\"nev16451470n5\"><ptxt id=\"nev16451470n6\"><phrase category=\"Title\" id=\"nev16451470n7\" phrase-urn=\"urn:x-nevis:phrase:0800c8af851d9362\">-</phrase></ptxt></entry><entry id=\"nev16451470n8\"><ptxt id=\"nev16451470n9\"><phrase category=\"Title\" id=\"nev16451470n10\" phrase-urn=\"urn:x-nevis:phrase:0800c8af851d9373\">U010400</phrase></ptxt></entry><entry id=\"nev16451471n1\"><ptxt id=\"nev16451471n2\"><phrase category=\"Title\" id=\"nev16451471n3\" phrase-urn=\"urn:x-nevis:phrase:0800c8af851d9363\">U023500</phrase></ptxt></entry><entry id=\"nev16451471n4\"><ptxt id=\"nev16451471n5\"><phrase category=\"Title\" id=\"nev16451471n6\" phrase-urn=\"urn:x-nevis:phrase:0800c8af851d9362\">-</phrase></ptxt></entry></row><row id=\"nev16451471n7\" rowsep=\"1\" valign=\"middle\"><entry id=\"nev16451471n8\"><ptxt id=\"nev16451471n9\"><phrase category=\"Title\" id=\"nev16451471n10\" phrase-urn=\"urn:x-nevis:phrase:0800c8af851d9377\">FSM</phrase></ptxt></entry><entry id=\"nev16451472n1\"><ptxt id=\"nev16451472n2\"><phrase category=\"Title\" id=\"nev16451472n3\" phrase-urn=\"urn:x-nevis:phrase:0800c8af851d936b\">U002888</phrase></ptxt></entry><entry id=\"nev16451472n4\"><ptxt id=\"nev16451472n5\"><phrase category=\"Title\" id=\"nev16451472n6\" phrase-urn=\"urn:x-nevis:phrase:0800c8af851d936d\">U002855</phrase></ptxt></entry><entry id=\"nev16451472n7\"><ptxt id=\"nev16451472n8\"><phrase category=\"Title\" id=\"nev16451472n9\" phrase-urn=\"urn:x-nevis:phrase:0800c8af851d936e\">U015100</phrase></ptxt></entry><entry id=\"nev16451472n10\"><ptxt id=\"nev16451473n1\"><phrase category=\"Title\" id=\"nev16451473n2\" phrase-urn=\"urn:x-nevis:phrase:0800c8af851d9362\">-</phrase></ptxt></entry><entry id=\"nev16451473n3\"><ptxt id=\"nev16451473n4\"><phrase category=\"Title\" id=\"nev16451473n5\" phrase-urn=\"urn:x-nevis:phrase:0800c8af851d9362\">-</phrase></ptxt></entry><entry id=\"nev16451473n6\"><ptxt id=\"nev16451473n7\"><phrase category=\"Title\" id=\"nev16451473n8\" phrase-urn=\"urn:x-nevis:phrase:0800c8af851d9362\">-</phrase></ptxt></entry><entry id=\"nev16451473n9\"><ptxt id=\"nev16451473n10\"><phrase category=\"Title\" id=\"nev16451474n1\" phrase-urn=\"urn:x-nevis:phrase:0800c8af851d9362\">-</phrase></ptxt></entry></row><row id=\"nev16451474n2\" rowsep=\"1\" valign=\"middle\"><entry id=\"nev16451474n3\"><ptxt id=\"nev16451474n4\"><phrase category=\"Title\" id=\"nev16451474n5\" phrase-urn=\"urn:x-nevis:phrase:0800c8af851d9379\">CVM</phrase></ptxt></entry><entry id=\"nev16451474n6\"><ptxt id=\"nev16451474n7\"><phrase category=\"Title\" id=\"nev16451474n8\" phrase-urn=\"urn:x-nevis:phrase:0800c8af851d9360\">U002800</phrase></ptxt></entry><entry id=\"nev16451474n9\"><ptxt id=\"nev16451474n10\"><phrase category=\"Title\" id=\"nev16451475n1\" phrase-urn=\"urn:x-nevis:phrase:0800c8af851d937a\">U03004A</phrase></ptxt></entry><entry id=\"nev16451475n2\"><ptxt id=\"nev16451475n3\"><phrase category=\"Title\" id=\"nev16451475n4\" phrase-urn=\"urn:x-nevis:phrase:0800c8af851d9362\">-</phrase></ptxt></entry><entry id=\"nev16451475n5\"><ptxt id=\"nev16451475n6\"><phrase category=\"Title\" id=\"nev16451475n7\" phrase-urn=\"urn:x-nevis:phrase:0800c8af851d9362\">-</phrase></ptxt></entry><entry id=\"nev16451475n8\"><ptxt id=\"nev16451475n9\"><phrase category=\"Title\" id=\"nev16451475n10\" phrase-urn=\"urn:x-nevis:phrase:0800c8af851d9362\">-</phrase></ptxt></entry><entry id=\"nev16451476n1\"><ptxt id=\"nev16451476n2\"><phrase category=\"Title\" id=\"nev16451476n3\" phrase-urn=\"urn:x-nevis:phrase:0800c8af851d9362\">-</phrase></ptxt></entry><entry id=\"nev16451476n4\"><ptxt id=\"nev16451476n5\"><phrase category=\"Title\" id=\"nev16451476n6\" phrase-urn=\"urn:x-nevis:phrase:0800c8af851d9362\">-</phrase></ptxt></entry></row></tbody></tgroup></table><note id=\"nev16451476n7\"><ptxt id=\"nev16451476n8\"><phrase category=\"Faulttracing\" id=\"nev16451476n9\" phrase-urn=\"urn:x-nevis:phrase:0800c8af82d740f9\">Более подробная информация приведена в разделе <emph etype=\"bold\">Устройство и коммуникация</emph>.</phrase></ptxt></note><para id=\"nev16451476n10\"><ptxt id=\"nev16451477n1\"><phrase category=\"Faulttracing\" id=\"nev16451477n2\" phrase-urn=\"urn:x-nevis:phrase:0800c8af81eb9478\">Выполните необходимый ремонт.</phrase></ptxt></para><list1 id=\"nev16451477n3\"><title id=\"nev16451477n4\"><phrase category=\"Title\" id=\"nev16451477n5\" phrase-urn=\"urn:x-nevis:phrase:0800c8af81ea4cd6\">Другая информация</phrase></title><item id=\"nev16451477n6\"><ptxt id=\"nev16451477n7\"><xref id=\"nev19320163n100\"><ref id=\"nev16451477n9\"><href title=\"VCC-278309-1, Общая информация о поиске неисправности в сети CAN\">ru-RU0900c8af85dea9b2#nev11218070n1</href></ref></xref></ptxt></item><item id=\"nev16451477n10\"><ptxt id=\"nev16451478n1\"><xref id=\"nev16451478n2\"><ref id=\"nev16451478n3\"><href title=\"VCC-285354-1, Описание зафиксированных значений\">ru-RU0900c8af8346c120#nev11400823n1</href></ref></xref></ptxt></item><item id=\"nev16451478n4\"><ptxt id=\"nev16451478n5\"><xref id=\"nev16451478n6\"><ref id=\"nev16451478n7\"><href title=\"VCC-167215-1, Beskrivning av statusidentifierare\">ru-RU0900c8af823e5d0c#KC09023161</href></ref></xref></ptxt></item><item id=\"nev16451478n8\"><ptxt id=\"nev16451478n9\"><xref id=\"nev16451478n10\"><ref id=\"nev16451479n1\"><href title=\"VCC-167216-1, Beskrivning av räknare\">ru-RU0900c8af823e5d0e#KC09047625</href></ref></xref></ptxt></item><item id=\"nev16451479n2\"><ptxt id=\"nev16451479n3\"><xref id=\"nev16451479n4\"><ref id=\"nev16451479n5\"><href title=\"VCC-285286-1, Описание параметров\">ru-RU0900c8af8504d3df#nev11394024n1</href></ref></xref></ptxt></item><item id=\"nev16451479n6\"><ptxt id=\"nev16451479n7\"><xref id=\"nev17204282n100\"><ref id=\"nev16451479n9\"><href title=\"VCC-407473-1, Расположение компонентов\">ru-RU0900c8af84c8c4fe#nev15229619n1</href></ref></xref></ptxt></item><item id=\"nev16451479n10\"><ptxt id=\"nev16451480n1\"><xref id=\"nev19320168n100\"><ref id=\"nev16451480n3\"><href title=\"VCC-407467-1, Характеристики сигналов\">ru-RU0900c8af84c8c49c#nev15229205n1</href></ref></xref></ptxt></item><item id=\"nev16451480n4\"><ptxt id=\"nev16451480n5\"><xref id=\"nev16451480n6\"><ref id=\"nev16451480n7\"><href title=\"VCC-123664-1, Проверка проводки и выводов\">ru-RU0900c8af8426e544#KC01108712</href></ref></xref></ptxt></item><item id=\"nev16451480n8\"><ptxt id=\"nev16451480n9\"><xref id=\"nev16451480n10\"><ref id=\"nev16451481n1\"><href title=\"VCC-285160-3, Подсоединение измерительного блока\">ru-RU0900c8af8506fcdc#nev11390876n1</href></ref></xref></ptxt></item></list1><grate><graphic id=\"nev16451481n2\"><href title=\"IMG-341203\">0900c8af84ea1634_80_60.gif</href></graphic></grate></test2></test1><question id=\"nev16451481n3\"><phrase category=\"Question\" id=\"nev16451481n4\" phrase-urn=\"urn:x-nevis:phrase:0800c8af81eb97f1\">После устранения неисправности выберите \"Продолжить\" (Continue).</phrase></question><resact-grp id=\"nev16451481n5\"><result button=\"cont\" comp=\"button\" highlight=\"0\" id=\"nev16451481n6\"></result><action id=\"nev16451481n7\" j2008use=\"1\" paperuse=\"0\" screenuse=\"1\"><return id=\"nev16451481n8\" value=\"DONE\"></return></action></resact-grp></node></testgrp></diagnostic></servinfosub>","description_plain":"Поиск неисправности\nПроверка связи\nМодули управления в локальной сети датчик-CAN могут обнаружить короткое замыкание, когда они посылают сигналы.Выполните поиск неисправности для кабелей на наличие короткого замыкания.\nМодули управления в локальной сети датчик-CAN могут обнаружить короткое замыкание, когда они посылают сигналы.\nВыполните поиск неисправности для кабелей на наличие короткого замыкания.\nПроверьте коммуникацию CAN между модулем дополнительной системы удерживания (SRS), модулем предельной скорости (CVM) и датчиком веса сидящего (OWS) (только рынок США/Канады).\nЕсли неисправность не была найдена:Выполните поиск неисправности в модуле предельной скорости (CVM).\nЕсли неисправность не была найдена:\nВыполните поиск неисправности в модуле предельной скорости (CVM).\nИнформация по поиску неисправностиНиже представлена подборка того, какие коды неисправности могут устанавливаться в локальной сети датчик-CAN (с учетом будущих изменений/обновлений).В таблице показано, где в локальной сети датчик-CAN могут быть неисправности.\nИнформация по поиску неисправности\nНиже представлена подборка того, какие коды неисправности могут устанавливаться в локальной сети датчик-CAN (с учетом будущих изменений/обновлений).В таблице показано, где в локальной сети датчик-CAN могут быть неисправности.\nНиже представлена подборка того, какие коды неисправности могут устанавливаться в локальной сети датчик-CAN (с учетом будущих изменений/обновлений).\nВ таблице показано, где в локальной сети датчик-CAN могут быть неисправности.\nТаблица кодов неисправности для локальной сети датчик-CAN\nКод неисправности в модуле управления\nКороткое замыкание, обрыв, внутренняя неисправность, поврежденный модуль управления (\"bus-off\")\nОшибка ID конфигурации\nSRS, сигнал отсутствует\nBCM, сигнал отсутствует\nFSM, сигнал отсутствует\nCVM, сигнал отсутствует\nOWS, сигнал отсутствует\nSRS\nU002800\n-\nU023500\nU015400\nМодуль управления тормозами\nU002888\nU002855\nU015100\nU010400\nFSM\nCVM\nU03004A\nБолее подробная информация приведена в разделе Устройство и коммуникация.\nВыполните необходимый ремонт.\nДругая информация\nru-RU0900c8af85dea9b2#nev11218070n1\nru-RU0900c8af8346c120#nev11400823n1\nru-RU0900c8af823e5d0c#KC09023161\nru-RU0900c8af823e5d0e#KC09047625\nru-RU0900c8af8504d3df#nev11394024n1\nru-RU0900c8af84c8c4fe#nev15229619n1\nru-RU0900c8af84c8c49c#nev15229205n1\nru-RU0900c8af8426e544#KC01108712\nru-RU0900c8af8506fcdc#nev11390876n1\nПосле устранения неисправности выберите \"Продолжить\" (Continue).","description_markdown":"# Поиск неисправности\n\nПоиск неисправности\n\nПроверка связи\n\nМодули управления в локальной сети датчик-CAN могут обнаружить короткое замыкание, когда они посылают сигналы.Выполните поиск неисправности для кабелей на наличие короткого замыкания.\n\nМодули управления в локальной сети датчик-CAN могут обнаружить короткое замыкание, когда они посылают сигналы.\n\nВыполните поиск неисправности для кабелей на наличие короткого замыкания.\n\nПроверьте коммуникацию CAN между модулем дополнительной системы удерживания (SRS), модулем предельной скорости (CVM) и датчиком веса сидящего (OWS) (только рынок США/Канады).\n\nЕсли неисправность не была найдена:Выполните поиск неисправности в модуле предельной скорости (CVM).\n\nЕсли неисправность не была найдена:\n\nВыполните поиск неисправности в модуле предельной скорости (CVM).\n\nИнформация по поиску неисправностиНиже представлена подборка того, какие коды неисправности могут устанавливаться в локальной сети датчик-CAN (с учетом будущих изменений/обновлений).В таблице показано, где в локальной сети датчик-CAN могут быть неисправности.\n\nИнформация по поиску неисправности\n\nНиже представлена подборка того, какие коды неисправности могут устанавливаться в локальной сети датчик-CAN (с учетом будущих изменений/обновлений).В таблице показано, где в локальной сети датчик-CAN могут быть неисправности.\n\nНиже представлена подборка того, какие коды неисправности могут устанавливаться в локальной сети датчик-CAN (с учетом будущих изменений/обновлений).\n\nВ таблице показано, где в локальной сети датчик-CAN могут быть неисправности.\n\nТаблица кодов неисправности для локальной сети датчик-CAN\n\nКод неисправности в модуле управления\n\nКороткое замыкание, обрыв, внутренняя неисправность, поврежденный модуль управления (\"bus-off\")\n\nОшибка ID конфигурации\n\nSRS, сигнал отсутствует\n\nBCM, сигнал отсутствует\n\nFSM, сигнал отсутствует\n\nCVM, сигнал отсутствует\n\nOWS, сигнал отсутствует\n\nSRS\n\nU002800\n\n-\n\nU023500\n\nU015400\n\nМодуль управления тормозами\n\nU002888\n\nU002855\n\nU015100\n\nU010400\n\nFSM\n\nCVM\n\nU03004A\n\nБолее подробная информация приведена в разделе Устройство и коммуникация.\n\nВыполните необходимый ремонт.\n\nДругая информация\n\nru-RU0900c8af85dea9b2#nev11218070n1\n\nru-RU0900c8af8346c120#nev11400823n1\n\nru-RU0900c8af823e5d0c#KC09023161\n\nru-RU0900c8af823e5d0e#KC09047625\n\nru-RU0900c8af8504d3df#nev11394024n1\n\nru-RU0900c8af84c8c4fe#nev15229619n1\n\nru-RU0900c8af84c8c49c#nev15229205n1\n\nru-RU0900c8af8426e544#KC01108712\n\nru-RU0900c8af8506fcdc#nev11390876n1\n\n## Вопрос\n\nПосле устранения неисправности выберите \"Продолжить\" (Continue).","xml_size":3160}