{"id":-2052924201,"chronicle_id":"0900c8af85a2dcd7","project_document_id":"0800c8af85a2dcd6","fk_document_type":4,"document_type":"diag:servinfosub","vcc_number":"VCC-453444-1","nevis_id":"0900c8af85a2dcd7","path":"VCC-453444-1\\0900c8af85a2dcd7_ru-RU.xml","title":"Информация кода неисправности TRM-U1A4B8F","xml_filename":"0900c8af85a2dcd7_ru-RU.xml","description_raw":"<?xml version=\"1.0\" encoding=\"utf-8\"?><servinfosub docno=\"VCC-453444\" id=\"nev18266258n1\" xml:lang=\"ru-RU\" IE-ID=\"ru-RU0900c8af85a2dcd7\"><title><phrase category=\"Title\" id=\"nev18266258n2\" phrase-urn=\"urn:x-nevis:phrase:0800c8af81eb9a54\">Информация кода неисправности</phrase><phrase category=\"Prefix\" id=\"nev18266258n3\" phrase-urn=\"urn:x-nevis:phrase:0800c8af8015c477\">TRM</phrase>-U1A4B8F</title><diagnostic id=\"nev18266258n4\" j2008use=\"1\" layout=\"0\" paperuse=\"1\" screenuse=\"1\" type=\"condition\"><condgrp id=\"nev18266258n5\"><condition id=\"nev18266258n6\" type=\"condition\"><ptxt id=\"nev18266258n7\"><phrase category=\"Condition\" id=\"nev18266258n8\" phrase-urn=\"urn:x-nevis:phrase:0800c8af8565febd\">Блок прицепа (TRM) передает и получает информацию стандартным методом последовательной связи по сети CAN (контроллерной локальной сети).</phrase></ptxt><ptxt id=\"nev18266258n9\"><phrase category=\"Condition\" id=\"nev18266258n10\" phrase-urn=\"urn:x-nevis:phrase:0800c8af82c4843c\">Код неисправности подается в том случае, если модуль управления обнаружит, что:</phrase></ptxt><list1 enumtype=\"d\" id=\"nev18266259n1\"><item id=\"nev18266259n2\"><ptxt id=\"nev18266259n3\"><phrase category=\"Condition\" id=\"nev18266259n4\" phrase-urn=\"urn:x-nevis:phrase:0800c8af82d76452\">Неправильный сигнал.</phrase></ptxt></item></list1><ptxt id=\"nev18266259n5\"><phrase category=\"Condition\" id=\"nev18266259n6\" phrase-urn=\"urn:x-nevis:phrase:0800c8af82c479d6\">Проверка модулем управления кодов неисправности начинается при следующих условиях:</phrase></ptxt><list1 enumtype=\"d\" id=\"nev18266259n7\"><item id=\"nev18266259n8\"><ptxt id=\"nev18266259n9\"><phrase category=\"Condition\" id=\"nev18266259n10\" phrase-urn=\"urn:x-nevis:phrase:0800c8af82ccc151\">Модуль управления под напряжением.</phrase></ptxt></item></list1><note id=\"nev18266260n1\"><ptxt id=\"nev18266260n2\"><phrase category=\"Condition\" id=\"nev18266260n3\" phrase-urn=\"urn:x-nevis:phrase:0800c8af82c4844b\">Модуль управления может обнаружить неисправность только когда будет начата проверка и код неисправности подается лишь тогда, когда будут выполнены условия.</phrase></ptxt></note><grate id=\"nev18266260n4\"><graphic id=\"nev18266260n5\"><href title=\"J3603330\">0900c8af81359ffd_80_60.gif</href></graphic></grate></condition></condgrp><condgrp id=\"nev18266260n6\"><condition id=\"nev18266260n7\" type=\"substitution\"><list1 enumtype=\"d\" id=\"nev18266260n8\"><item id=\"nev18266260n9\"><ptxt id=\"nev18266260n10\"><phrase category=\"Substitution\" id=\"nev18266261n1\" phrase-urn=\"urn:x-nevis:phrase:0800c8af81eb9984\">Отсутствует.</phrase></ptxt></item></list1></condition><ps id=\"nev18266261n2\"><list1 enumtype=\"d\" id=\"nev18266261n3\"><item id=\"nev18266261n4\"><ptxt id=\"nev18266261n5\"><phrase category=\"Condition\" id=\"nev18266261n6\" phrase-urn=\"urn:x-nevis:phrase:0800c8af8565fed2\">Блок прицепа (TRM) не имеет контакта с процессором B.</phrase></ptxt></item></list1></ps></condgrp><condgrp id=\"nev18266261n7\"><condition id=\"nev18266261n8\" type=\"symptom\"><list1 enumtype=\"d\" id=\"nev18266261n9\"><item id=\"nev18266261n10\"><ptxt id=\"nev18266262n1\"><phrase category=\"Symptom CSC\" id=\"nev18266262n2\" phrase-urn=\"urn:x-nevis:phrase:0800c8af8388f147\">JV, Свет прицепа/Не работает</phrase></ptxt></item></list1></condition></condgrp></diagnostic></servinfosub>","description_plain":"Информация кода неисправностиTRM-U1A4B8F\nИнформация кода неисправности\nTRM\nБлок прицепа (TRM) передает и получает информацию стандартным методом последовательной связи по сети CAN (контроллерной локальной сети).\nКод неисправности подается в том случае, если модуль управления обнаружит, что:\nНеправильный сигнал.\nПроверка модулем управления кодов неисправности начинается при следующих условиях:\nМодуль управления под напряжением.\nМодуль управления может обнаружить неисправность только когда будет начата проверка и код неисправности подается лишь тогда, когда будут выполнены условия.\nОтсутствует.\nБлок прицепа (TRM) не имеет контакта с процессором B.\nJV, Свет прицепа/Не работает","description_markdown":"# Информация кода неисправностиTRM-U1A4B8F\n\nИнформация кода неисправности\n\nTRM\n\nБлок прицепа (TRM) передает и получает информацию стандартным методом последовательной связи по сети CAN (контроллерной локальной сети).\n\nКод неисправности подается в том случае, если модуль управления обнаружит, что:\n\nНеправильный сигнал.\n\nПроверка модулем управления кодов неисправности начинается при следующих условиях:\n\nМодуль управления под напряжением.\n\nМодуль управления может обнаружить неисправность только когда будет начата проверка и код неисправности подается лишь тогда, когда будут выполнены условия.\n\nОтсутствует.\n\nБлок прицепа (TRM) не имеет контакта с процессором B.\n\nJV, Свет прицепа/Не работает","xml_size":1340}