{"id":-2140702042,"chronicle_id":"0900c8af80677aa6","project_document_id":"0800c8af80677ab7","fk_document_type":4,"document_type":"diag:servinfosub","vcc_number":"VCC-027943-1","nevis_id":"0900c8af80677aa6","path":"VCC-027943-1\\0900c8af80677aa6_ru-RU.xml","title":"Проверка общей точки заземления","xml_filename":"0900c8af80677aa6_ru-RU.xml","description_raw":"<?xml version=\"1.0\" encoding=\"utf-8\"?><servinfosub docno=\"VCC-027943\" id=\"KC02037725\" xml:lang=\"ru-RU\" IE-ID=\"ru-RU0900c8af80677aa6\"><title><phrase id=\"KC08339863\">Проверка общей точки заземления</phrase></title><subtitle><phrase id=\"KC08339864\">1-2-3, 3-1-4 и 4-1-1</phrase></subtitle><diagnostic type=\"test\"><testgrp id=\"KC02037726\" j2008use=\"1\" paperuse=\"1\" resumable=\"1\" screenuse=\"1\" testgrp-id=\"eab0\" x=\"120\" y=\"120\" IE-ID=\"ru-RU0900c8af80677aa6_KC02037726\"><title><phrase id=\"KC08339865\">Предварительная информация</phrase></title><node><test1><test2><grate><graphic id=\"KC08339866\"><href title=\"A2300556\">0900c8af80120426_0_0.gif</href></graphic><graphtext><para><ptxt><phrase id=\"KC08339867\">Этот тест предназначен для поиска неисправности, для которой было записано более одного кода DTC. Если в памяти находятся перечисленные ниже коды DTC и состояния, то имеет смысл продолжить тестирование.</phrase></ptxt></para><list1><item><ptxt><phrase id=\"KC08339868\">1-2-3 Сигнал ECT. Слишком высокий уровень сигнала</phrase></ptxt></item><item><ptxt><phrase id=\"KC08339869\">3-1-4 Сигнал датчика CMP</phrase></ptxt></item><item><ptxt><phrase id=\"KC08339870\">4-1-1 Сигнал датчика TP. Слишком высокий уровень сигнала</phrase></ptxt></item></list1><ptxt><phrase id=\"KC08339871\">и, возможно,</phrase></ptxt><list1><item><ptxt><phrase id=\"KC08339872\">4-1-3 сигнал датчика температуры EGR</phrase></ptxt></item></list1></graphtext></grate></test2></test1><question>Продолжить ли тестирование?</question><resact-grp><result button=\"yes\" comp=\"button\" highlight=\"0\"></result><action j2008use=\"1\" paperuse=\"1\" screenuse=\"1\"><ptxt><xref><ref id=\"KC08339873\"><href title=\"Проверка на размыкание\">ru-RU0900c8af80677aa6#KC02037727</href></ref></xref></ptxt></action></resact-grp><resact-grp><result button=\"no\" comp=\"button\" highlight=\"0\"></result><action j2008use=\"1\" paperuse=\"0\" screenuse=\"1\"><return value=\"FAULT NOT FOUND\"></return></action></resact-grp></node></testgrp><testgrp id=\"KC02037727\" j2008use=\"1\" paperuse=\"0\" resumable=\"1\" screenuse=\"1\" testgrp-id=\"eab1\" x=\"120\" y=\"200\"><title><phrase id=\"KC08339874\">Проверка на размыкание</phrase></title><node><test1><test2><ptxt><phrase id=\"KC08339875\">Разъем #A18 модуля управления является общей точкой заземления для следующих компонентов:</phrase></ptxt><list1 type=\"unordered\"><item><ptxt><phrase id=\"KC08339876\">Датчик ECT (разъем 2)</phrase></ptxt></item><item><ptxt><phrase id=\"KC08339877\">Датчик TP (разъем 1)</phrase></ptxt></item><item><ptxt><phrase id=\"KC08339878\">Датчик CMP (разъем 1)</phrase></ptxt></item></list1><ptxt><phrase id=\"KC08339879\">Будет установлено более одного DTC если имел место обрыв общего провода на #A18.</phrase></ptxt><diaglist><dgraphic><dgraphic2><graphic id=\"KC08339880\"><href title=\"A3000036\">0900c8af80054d47_0_0.gif</href></graphic><smarttool active=\"press\" id=\"KC08339881\" toolname=\"ODAH\"><href title=\"ODAH, \">0800c8af80070d96</href></smarttool></dgraphic2></dgraphic><ditem><ditemtext><ptxt><phrase id=\"KC08339882\">Проверьте провод между выводами #A18 модуля управления и одним из компонентов на контактное сопротивление и окисление, смотрите<xref><ref id=\"KC08339883\"><href title=\"VCC-018853-1, Проверка проводки и выводов. Постоянные неисправности\">ru-RU0900c8af80be4147#KC01106363</href></ref></xref>и размыкание, смотрите<xref><ref id=\"KC08339884\"><href title=\"VCC-018853-1, Проверка проводки и выводов. Постоянные неисправности\">ru-RU0900c8af80be4147#KC01106360</href></ref></xref>.</phrase></ptxt></ditemtext></ditem></diaglist><grate><graphic id=\"KC08339885\" width=\"column\"><href title=\"S150716\">0900c8af8012d889_0_0.gif</href></graphic></grate></test2></test1><question>После устранения неисправности выберите \"Continue\" (Продолжить).</question><resact-grp><result button=\"cont\" comp=\"button\" highlight=\"0\"></result><action j2008use=\"1\" paperuse=\"0\" screenuse=\"1\"><ptxt><xref><ref id=\"KC08339886\"><href title=\"Проверка\">ru-RU0900c8af80677aa6#KC02037728</href></ref></xref></ptxt></action></resact-grp></node></testgrp><testgrp id=\"KC02037728\" j2008use=\"1\" paperuse=\"0\" resumable=\"1\" screenuse=\"1\" testgrp-id=\"verieab1\" x=\"280\" y=\"120\"><title><phrase id=\"KC08339887\">Проверка</phrase></title><subcalloutnode><diagcallout><xref><ref id=\"KC08339888\"><href title=\"VCC-020545-1, Проверьте\">ru-RU0900c8af803f01d6#KC01398187</href></ref></xref></diagcallout><rescall-grp><result comp=\"string\" highlight=\"0\" op=\"eq\" return=\"VERIFICATION FAILED\"></result><calloutaction><ptxt><xref><ref id=\"KC08339889\"><href title=\"Информация для поиска неисправностей\">ru-RU0900c8af80677aa6#KC02037729</href></ref></xref></ptxt></calloutaction></rescall-grp><rescall-grp><result comp=\"string\" highlight=\"0\" op=\"eq\" return=\"VERIFIED\"></result><calloutaction><return value=\"FAULT FOUND\"></return></calloutaction></rescall-grp></subcalloutnode></testgrp><testgrp id=\"KC02037729\" j2008use=\"1\" paperuse=\"0\" resumable=\"1\" screenuse=\"1\" testgrp-id=\"info1\" x=\"440\" y=\"120\"><title><phrase id=\"KC08339890\">Информация для поиска неисправностей</phrase></title><subcalloutnode><diagcallout><xref><ref id=\"KC08339891\"><href title=\"VCC-002087-1, Информация\">ru-RU0900c8af8006ff94#KC01106273</href></ref></xref></diagcallout><rescall-grp><result comp=\"string\" highlight=\"0\" op=\"eq\" return=\"FAULTTRACING FAILED\"></result><calloutaction><return value=\"FAULTTRACING FAILED\"></return></calloutaction></rescall-grp><rescall-grp><result comp=\"string\" highlight=\"0\" op=\"eq\" return=\"NEW TRY\"></result><calloutaction><ptxt><xref><ref id=\"KC08339892\"><href title=\"Проверка на размыкание\">ru-RU0900c8af80677aa6#KC02037727</href></ref></xref></ptxt></calloutaction></rescall-grp></subcalloutnode></testgrp></diagnostic></servinfosub>","description_plain":"Проверка общей точки заземления\n1-2-3, 3-1-4 и 4-1-1\nПредварительная информация\nЭтот тест предназначен для поиска неисправности, для которой было записано более одного кода DTC. Если в памяти находятся перечисленные ниже коды DTC и состояния, то имеет смысл продолжить тестирование.\n1-2-3 Сигнал ECT. Слишком высокий уровень сигнала\n3-1-4 Сигнал датчика CMP\n4-1-1 Сигнал датчика TP. Слишком высокий уровень сигнала\nи, возможно,\n4-1-3 сигнал датчика температуры EGR\nПродолжить ли тестирование?\nru-RU0900c8af80677aa6#KC02037727\nПроверка на размыкание\nРазъем #A18 модуля управления является общей точкой заземления для следующих компонентов:\nДатчик ECT (разъем 2)\nДатчик TP (разъем 1)\nДатчик CMP (разъем 1)\nБудет установлено более одного DTC если имел место обрыв общего провода на #A18.\nПроверьте провод между выводами #A18 модуля управления и одним из компонентов на контактное сопротивление и окисление, смотритеru-RU0900c8af80be4147#KC01106363и размыкание, смотритеru-RU0900c8af80be4147#KC01106360.\nПосле устранения неисправности выберите \"Continue\" (Продолжить).\nru-RU0900c8af80677aa6#KC02037728\nПроверка\nru-RU0900c8af80677aa6#KC02037729\nИнформация для поиска неисправностей","description_markdown":"# Проверка общей точки заземления\n\nПроверка общей точки заземления\n\n1-2-3, 3-1-4 и 4-1-1\n\nПредварительная информация\n\nЭтот тест предназначен для поиска неисправности, для которой было записано более одного кода DTC. Если в памяти находятся перечисленные ниже коды DTC и состояния, то имеет смысл продолжить тестирование.\n\n1-2-3 Сигнал ECT. Слишком высокий уровень сигнала\n\n3-1-4 Сигнал датчика CMP\n\n4-1-1 Сигнал датчика TP. Слишком высокий уровень сигнала\n\nи, возможно,\n\n4-1-3 сигнал датчика температуры EGR\n\n## Вопрос\n\nПродолжить ли тестирование?\n\nru-RU0900c8af80677aa6#KC02037727\n\nПроверка на размыкание\n\nРазъем #A18 модуля управления является общей точкой заземления для следующих компонентов:\n\nДатчик ECT (разъем 2)\n\nДатчик TP (разъем 1)\n\nДатчик CMP (разъем 1)\n\nБудет установлено более одного DTC если имел место обрыв общего провода на #A18.\n\nПроверьте провод между выводами #A18 модуля управления и одним из компонентов на контактное сопротивление и окисление, смотритеru-RU0900c8af80be4147#KC01106363и размыкание, смотритеru-RU0900c8af80be4147#KC01106360.\n\n## Вопрос\n\nПосле устранения неисправности выберите \"Continue\" (Продолжить).\n\nru-RU0900c8af80677aa6#KC02037728\n\nПроверка\n\nru-RU0900c8af80677aa6#KC02037729\n\nИнформация для поиска неисправностей","xml_size":1979}