{"id":-2140992409,"chronicle_id":"0900c8af80630c67","project_document_id":"0800c8af80630c78","fk_document_type":4,"document_type":"diag:servinfosub","vcc_number":"VCC-020671-1","nevis_id":"0900c8af80630c67","path":"VCC-020671-1\\0900c8af80630c67_ru-RU.xml","title":"Ошибочный сигнал","xml_filename":"0900c8af80630c67_ru-RU.xml","description_raw":"<?xml version=\"1.0\" encoding=\"utf-8\"?><servinfosub docno=\"VCC-020671\" id=\"KC02126917\" xml:lang=\"ru-RU\" IE-ID=\"ru-RU0900c8af80630c67\"><title><phrase category=\"\" id=\"KC08117619\" phrase-urn=\"urn:x-nevis:phrase:0800c8af81d79494\">Ошибочный сигнал</phrase></title><subtitle><phrase category=\"\" id=\"KC08117620\" phrase-urn=\"urn:x-nevis:phrase:0800c8af81d79495\">5-3-1 Группа A силового каскада</phrase></subtitle><diagnostic type=\"test\"><testgrp id=\"KC02333677\" j2008use=\"1\" paperuse=\"1\" resumable=\"1\" screenuse=\"1\" testgrp-id=\"ebn2\" x=\"120\" y=\"80\" IE-ID=\"ru-RU0900c8af80630c67_KC02333677\"><title><phrase category=\"\" id=\"KC08117621\" phrase-urn=\"urn:x-nevis:phrase:0800c8af81d79497\">Проверка форсунок</phrase></title><node><test1><diaglist></diaglist><test2><diaglist><dgraphic><dgraphic2><graphic id=\"KC08117622\"><href title=\"A0800023\">0900c8af80054332_0_0.gif</href></graphic><smarttool active=\"press\" id=\"KC08117623\" toolname=\"EM43D3\"><href title=\"EM43D3, Diagnostic test mode 3\">0800c8af80628349</href></smarttool></dgraphic2></dgraphic><ditem><ditemtext><ptxt><phrase category=\"\" id=\"KC08117624\" phrase-urn=\"urn:x-nevis:phrase:0800c8af81d79498\">Запустите DTM 3.</phrase></ptxt><warning><ptxt><phrase category=\"\" id=\"KC08117625\" phrase-urn=\"urn:x-nevis:phrase:0800c8af81d79499\">Последовательность DTM автоматически запустит  вентилятор охлаждения двигателя. </phrase></ptxt></warning><ptxt><phrase category=\"\" id=\"KC08117626\" phrase-urn=\"urn:x-nevis:phrase:0800c8af81d7949a\">О последовательности DTM 3 смотрите <xref><ref id=\"KC08117627\"><href title=\"VCC-021383-1, Вывод данных диагностики\">ru-RU0900c8af8042110e#KC01463050</href></ref></xref>.</phrase></ptxt></ditemtext></ditem><ditem><hint><ptxt><phrase category=\"\" id=\"KC08117628\" phrase-urn=\"urn:x-nevis:phrase:0800c8af81d7949c\">Для нормальной работы DTM 3 должны быть  подсоединены три форсунки. Таким образом тест может  выполняться несколько раз для разных форсунок.</phrase></ptxt></hint></ditem><ditem><ptxt><phrase category=\"\" id=\"KC08117629\" phrase-urn=\"urn:x-nevis:phrase:0800c8af81d7949d\">Проверьте, хорошо ли работают форсунки.</phrase></ptxt></ditem></diaglist></test2></test1><question>Нормально ли работают форсунки?</question><resact-grp><result button=\"yes\" comp=\"button\" highlight=\"0\"></result><action j2008use=\"1\" paperuse=\"1\" screenuse=\"1\"><ptxt><xref><ref id=\"KC08117630\"><href title=\"Проверка клапана EVAP\">ru-RU0900c8af80630c67#KC02333690</href></ref></xref></ptxt></action></resact-grp><resact-grp><result button=\"no\" comp=\"button\" highlight=\"0\"></result><action j2008use=\"1\" paperuse=\"1\" screenuse=\"1\"><ptxt><xref><ref id=\"KC08117631\"><href title=\"Проверка подачи питания на форсунки\">ru-RU0900c8af80630c67#KC02333678</href></ref></xref></ptxt></action></resact-grp></node></testgrp><testgrp id=\"KC02333678\" j2008use=\"1\" paperuse=\"1\" resumable=\"1\" screenuse=\"1\" testgrp-id=\"ebn3\" x=\"120\" y=\"160\"><title><phrase category=\"\" id=\"KC08117632\" phrase-urn=\"urn:x-nevis:phrase:0800c8af81d7949e\">Проверка подачи питания на форсунки</phrase></title><node><test1><diaglist><dgraphic><dgraphic1><graphic id=\"KC08117633\"><href title=\"A3000040\">0900c8af80054d55_0_0.gif</href></graphic></dgraphic1><dgraphic2><graphic id=\"KC08117634\"><href title=\"A3000244\">0900c8af80054d7a_0_0.gif</href></graphic></dgraphic2></dgraphic><ditem><ptxt><phrase category=\"\" id=\"KC08117635\" phrase-urn=\"urn:x-nevis:phrase:0800c8af81d7949f\">Выключите зажигание.</phrase></ptxt></ditem><ditem><ptxt><phrase category=\"\" id=\"KC08117636\" phrase-urn=\"urn:x-nevis:phrase:0800c8af81d794a0\">Отключите соответствующую форсунку.</phrase></ptxt></ditem><ditem><ptxt><phrase category=\"\" id=\"KC08117637\" phrase-urn=\"urn:x-nevis:phrase:0800c8af81d794a2\">Включите зажигание.</phrase></ptxt></ditem></diaglist><test2><diaglist><dgraphic><dgraphic1><graphic id=\"KC08117638\"><href title=\"A3000223\">0900c8af80054d6f_0_0.gif</href></graphic></dgraphic1><dgraphic2><graphic id=\"KC08117639\"><href title=\"A3000031\">0900c8af80054d45_0_0.gif</href></graphic><smarttool id=\"KC08117640\" toolname=\"VDCD40\"><href title=\"VDCD40, voltage DC digital meter 40 volt\">0800c8af80114135</href></smarttool></dgraphic2></dgraphic><ditem><ditemtext><ptxt><phrase category=\"\" id=\"KC08117641\" phrase-urn=\"urn:x-nevis:phrase:0800c8af81d794a3\">Подсоедините вольтметр между  разъемом 1 форсунки и землей.</phrase></ptxt></ditemtext></ditem></diaglist></test2></test1><question>Вольтметр должен показывать напряжение  аккумулятора. </question><resact-grp><result button=\"ok\" comp=\"button\" highlight=\"0\"></result><action j2008use=\"1\" paperuse=\"1\" screenuse=\"1\"><ptxt><xref><ref id=\"KC08117642\"><href title=\"Проверьте форсунку\">ru-RU0900c8af80630c67#KC02333680</href></ref></xref></ptxt></action></resact-grp><resact-grp><result button=\"notok\" comp=\"button\" highlight=\"0\"></result><action j2008use=\"0\" paperuse=\"1\" screenuse=\"0\"><ptxt>Проверьте провод между  разъемом 3 главного реле (2/32) и разъемом 1 форсунки на  предмет размыкания, смотрите  <xref><ref id=\"KC08117643\"><href title=\"VCC-018853-1, Проверка проводки и выводов. Постоянные неисправности\">ru-RU0900c8af80be4147#KC01106360</href></ref></xref>.</ptxt></action><action j2008use=\"1\" paperuse=\"0\" screenuse=\"1\"><ptxt><xref><ref id=\"KC08117644\"><href title=\"Проверка на размыкание\">ru-RU0900c8af80630c67#KC02333679</href></ref></xref></ptxt></action></resact-grp></node></testgrp><testgrp id=\"KC02333679\" j2008use=\"1\" paperuse=\"0\" resumable=\"1\" screenuse=\"1\" testgrp-id=\"ebn3-1\" x=\"280\" y=\"160\"><title><phrase category=\"\" id=\"KC08117645\" phrase-urn=\"urn:x-nevis:phrase:0800c8af81d794a4\">Проверка на размыкание</phrase></title><node><test1><test2><diaglist><dgraphic><dgraphic1><graphic id=\"KC08117646\"><href title=\"A3000223\">0900c8af80054d6f_0_0.gif</href></graphic></dgraphic1><dgraphic2><graphic id=\"KC08117647\"><href title=\"A3000036\">0900c8af80054d47_0_0.gif</href></graphic><smarttool active=\"press\" id=\"KC08117648\" toolname=\"ODAH\"><href title=\"ODAH, \">0800c8af80070d96</href></smarttool></dgraphic2></dgraphic><ditem><ditemtext><ptxt><phrase category=\"\" id=\"KC08117649\" phrase-urn=\"urn:x-nevis:phrase:0800c8af81d794a5\">Проверьте провод между разъемом 3 главного реле  (2/32) и разъемом 1 форсунки на предмет размыкания, смотрите  <xref><ref id=\"KC08117650\"><href title=\"VCC-018853-1, Проверка проводки и выводов. Постоянные неисправности\">ru-RU0900c8af80be4147#KC01106360</href></ref></xref>.</phrase></ptxt></ditemtext></ditem></diaglist><grate><graphic id=\"KC08117651\"><href title=\"A8700264\">0900c8af800570bd_0_0.gif</href></graphic></grate></test2></test1><question>После устранения неисправности выберите \"Continue\"  (Продолжить).</question><resact-grp><result button=\"cont\" comp=\"button\" highlight=\"0\"></result><action j2008use=\"1\" paperuse=\"0\" screenuse=\"1\"><return value=\"FAULT FOUND\"></return></action></resact-grp></node></testgrp><testgrp id=\"KC02333680\" j2008use=\"1\" paperuse=\"1\" resumable=\"1\" screenuse=\"1\" testgrp-id=\"ebn4\" x=\"120\" y=\"240\"><title><phrase category=\"\" id=\"KC08117652\" phrase-urn=\"urn:x-nevis:phrase:0800c8af81d794a6\">Проверьте форсунку</phrase></title><node><test1><diaglist><dgraphic><dgraphic1><graphic id=\"KC08117653\"><href title=\"A3000037\">0900c8af80054d4b_0_0.gif</href></graphic></dgraphic1><dgraphic2><graphic id=\"KC08117654\"><href title=\"A3000242\">0900c8af80054d75_0_0.gif</href></graphic></dgraphic2></dgraphic><ditem><ptxt><phrase category=\"\" id=\"KC08117655\" phrase-urn=\"urn:x-nevis:phrase:0800c8af81d794a7\">Выключите зажигание.</phrase></ptxt></ditem><ditem><ptxt><phrase category=\"\" id=\"KC08117656\" phrase-urn=\"urn:x-nevis:phrase:0800c8af81d794a8\">Отсоедините форсунку.</phrase></ptxt></ditem></diaglist><test2><diaglist><dgraphic><dgraphic1><graphic id=\"KC08117657\"><href title=\"A3000211\">0900c8af801280d9_0_0.gif</href></graphic></dgraphic1><dgraphic2><graphic id=\"KC08117658\"><href title=\"A3000036\">0900c8af80054d47_0_0.gif</href></graphic><smarttool id=\"KC08117659\" toolname=\"ODA\"><href title=\"ODA, Ohm digital meter autorange\">0800c8af80070e43</href></smarttool></dgraphic2></dgraphic><ditem><ditemtext><ptxt><phrase category=\"\" id=\"KC08117660\" phrase-urn=\"urn:x-nevis:phrase:0800c8af81d794ad\">Подсоедините омметр между разъемами 1  и 2 форсунки.</phrase></ptxt></ditemtext></ditem></diaglist></test2></test1><question>Омметр должен показывать приблизительно 14,5 Ω при +20°C .</question><resact-grp><result button=\"ok\" comp=\"button\" highlight=\"0\"></result><action j2008use=\"1\" paperuse=\"1\" screenuse=\"1\"><ptxt><xref><ref id=\"KC08117661\"><href title=\"Проверка сигнального провода\">ru-RU0900c8af80630c67#KC02333682</href></ref></xref></ptxt></action></resact-grp><resact-grp><result button=\"notok\" comp=\"button\" highlight=\"0\"></result><action j2008use=\"0\" paperuse=\"1\" screenuse=\"0\"><ptxt>Проверьте работу с новой  форсункой.</ptxt></action><action j2008use=\"1\" paperuse=\"0\" screenuse=\"1\"><ptxt><xref><ref id=\"KC08117662\"><href title=\"Замена компонента\">ru-RU0900c8af80630c67#KC02333681</href></ref></xref></ptxt></action></resact-grp></node></testgrp><testgrp id=\"KC02333681\" j2008use=\"1\" paperuse=\"0\" resumable=\"1\" screenuse=\"1\" testgrp-id=\"ebn4-1\" x=\"280\" y=\"240\"><title><phrase category=\"\" id=\"KC08117663\" phrase-urn=\"urn:x-nevis:phrase:0800c8af81d794ae\">Замена компонента</phrase></title><node><test1><test2><diaglist><ditem><ptxt><phrase category=\"\" id=\"KC08117664\" phrase-urn=\"urn:x-nevis:phrase:0800c8af81d794b0\">Проверьте работу с новой форсункой.</phrase></ptxt></ditem></diaglist><grate><graphic id=\"KC08117665\" width=\"column\"><href title=\"S2300215\">0900c8af8012e2f9_0_0.gif</href></graphic></grate></test2></test1><question>После устранения неисправности выберите \"Continue\"  (Продолжить).</question><resact-grp><result button=\"cont\" comp=\"button\" highlight=\"0\"></result><action j2008use=\"1\" paperuse=\"0\" screenuse=\"1\"><return value=\"FAULT FOUND\"></return></action></resact-grp></node></testgrp><testgrp id=\"KC02333682\" j2008use=\"1\" paperuse=\"1\" resumable=\"1\" screenuse=\"1\" testgrp-id=\"ebn5\" x=\"120\" y=\"320\"><title><phrase category=\"\" id=\"KC08117666\" phrase-urn=\"urn:x-nevis:phrase:0800c8af81d794b1\">Проверка сигнального провода</phrase></title><node><test1><diaglist><dgraphic><dgraphic1><graphic id=\"KC08117667\"><href title=\"A3000040\">0900c8af80054d55_0_0.gif</href></graphic></dgraphic1><dgraphic2><graphic id=\"KC08117668\"><href title=\"A3000242\">0900c8af80054d75_0_0.gif</href></graphic></dgraphic2></dgraphic><ditem><ptxt><phrase category=\"\" id=\"KC08117669\" phrase-urn=\"urn:x-nevis:phrase:0800c8af81d794b2\">Включите зажигание.</phrase></ptxt></ditem><ditem><ptxt><phrase category=\"\" id=\"KC08117670\" phrase-urn=\"urn:x-nevis:phrase:0800c8af81d794b3\">Отсоедините форсунку.</phrase></ptxt></ditem></diaglist><test2><diaglist><dgraphic><dgraphic1><graphic id=\"KC08117671\"><href title=\"A3000223\">0900c8af80054d6f_0_0.gif</href></graphic></dgraphic1><dgraphic2><graphic id=\"KC08117672\"><href title=\"A3000031\">0900c8af80054d45_0_0.gif</href></graphic><smarttool id=\"KC08117673\" toolname=\"VDCD40\"><href title=\"VDCD40, voltage DC digital meter 40 volt\">0800c8af80114135</href></smarttool></dgraphic2></dgraphic><ditem><ditemtext><ptxt><phrase category=\"\" id=\"KC08117674\" phrase-urn=\"urn:x-nevis:phrase:0800c8af81d794b5\">Подсоедините вольтметр между  разъемом 2 форсунки и землей.</phrase></ptxt></ditemtext></ditem></diaglist></test2></test1><question>Вольтметр должен показывать приблизительно 0 В. </question><resact-grp><result button=\"ok\" comp=\"button\" highlight=\"0\"></result><action j2008use=\"1\" paperuse=\"1\" screenuse=\"1\"><ptxt><xref><ref id=\"KC08117675\"><href title=\"Проверка сопротивления между сигнальным &#xA;проводом и землей&#xA;\">ru-RU0900c8af80630c67#KC02333684</href></ref></xref></ptxt></action></resact-grp><resact-grp><result button=\"notok\" comp=\"button\" highlight=\"0\"></result><action j2008use=\"0\" paperuse=\"1\" screenuse=\"0\"><ptxt>Проверьте провод между  разъемом 2 форсунки и ECM #A10, #A38, #A24, #A23 или #A9 (в зависимости от того, какая именно форсунка не работает)  на предмет короткого замыкания на источник питания,  смотрите <xref><ref id=\"KC08117676\"><href title=\"VCC-018853-1, Проверка проводки и выводов. Постоянные неисправности\">ru-RU0900c8af80be4147#KC01106854</href></ref></xref>.</ptxt></action><action j2008use=\"1\" paperuse=\"0\" screenuse=\"1\"><ptxt><xref><ref id=\"KC08117677\"><href title=\"Проверка на короткое замыкание\">ru-RU0900c8af80630c67#KC02333683</href></ref></xref></ptxt></action></resact-grp></node></testgrp><testgrp id=\"KC02333683\" j2008use=\"1\" paperuse=\"0\" resumable=\"1\" screenuse=\"1\" testgrp-id=\"ebn5-1\" x=\"280\" y=\"320\"><title><phrase category=\"\" id=\"KC08117678\" phrase-urn=\"urn:x-nevis:phrase:0800c8af81d794b6\">Проверка на короткое замыкание</phrase></title><node><test1><test2><diaglist><dgraphic><dgraphic1><graphic id=\"KC08117679\"><href title=\"A3000223\">0900c8af80054d6f_0_0.gif</href></graphic></dgraphic1><dgraphic2><graphic id=\"KC08117680\"><href title=\"A3000036\">0900c8af80054d47_0_0.gif</href></graphic><smarttool active=\"press\" id=\"KC08117681\" toolname=\"ODAH\"><href title=\"ODAH, \">0800c8af80070d96</href></smarttool></dgraphic2></dgraphic><ditem><ditemtext><ptxt><phrase category=\"\" id=\"KC08117682\" phrase-urn=\"urn:x-nevis:phrase:0800c8af81d794b7\">Проверьте провод между разъемом 2 форсунки и ECM #A10, #A38, #A24, #A23 или #A9 (в зависимости от того, какая именно форсунка  не работает) на предмет короткого замыкания на источник  питания, смотрите <xref><ref id=\"KC08117683\"><href title=\"VCC-018853-1, Проверка проводки и выводов. Постоянные неисправности\">ru-RU0900c8af80be4147#KC01106854</href></ref></xref>.</phrase></ptxt></ditemtext></ditem></diaglist><grate><graphic id=\"KC08117684\"><href title=\"A8700266\">0900c8af800570c2_0_0.gif</href></graphic></grate></test2></test1><question>После устранения неисправности выберите \"Continue\"  (Продолжить).</question><resact-grp><result button=\"cont\" comp=\"button\" highlight=\"0\"></result><action j2008use=\"1\" paperuse=\"0\" screenuse=\"1\"><return value=\"FAULT FOUND\"></return></action></resact-grp></node></testgrp><testgrp id=\"KC02333684\" j2008use=\"1\" paperuse=\"1\" resumable=\"1\" screenuse=\"1\" testgrp-id=\"ebn6\" x=\"120\" y=\"400\"><title><phrase category=\"\" id=\"KC08117685\" phrase-urn=\"urn:x-nevis:phrase:0800c8af81d794b9\">Проверка сопротивления между сигнальным  проводом и землей </phrase></title><node><test1><diaglist><dgraphic><dgraphic1><graphic id=\"KC08117686\"><href title=\"A3000037\">0900c8af80054d4b_0_0.gif</href></graphic></dgraphic1><dgraphic2><graphic id=\"KC08117687\"><href title=\"A3000242\">0900c8af80054d75_0_0.gif</href></graphic></dgraphic2></dgraphic><ditem><ptxt><phrase category=\"\" id=\"KC08117688\" phrase-urn=\"urn:x-nevis:phrase:0800c8af81d794ba\">Выключите зажигание.</phrase></ptxt></ditem><ditem><ptxt><phrase category=\"\" id=\"KC08117689\" phrase-urn=\"urn:x-nevis:phrase:0800c8af81d794bb\">Подождите примерно 150 сек.</phrase></ptxt></ditem><ditem><ptxt><phrase category=\"\" id=\"KC08117690\" phrase-urn=\"urn:x-nevis:phrase:0800c8af81d794bc\">Отсоедините форсунку.</phrase></ptxt></ditem></diaglist><test2><diaglist><dgraphic><dgraphic1><graphic id=\"KC08117691\"><href title=\"A3000223\">0900c8af80054d6f_0_0.gif</href></graphic></dgraphic1><dgraphic2><graphic id=\"KC08117692\"><href title=\"A3000036\">0900c8af80054d47_0_0.gif</href></graphic><smarttool id=\"KC08117693\" toolname=\"ODA\"><href title=\"ODA, Ohm digital meter autorange\">0800c8af80070e43</href></smarttool></dgraphic2></dgraphic><ditem><ditemtext><ptxt><phrase category=\"\" id=\"KC08117694\" phrase-urn=\"urn:x-nevis:phrase:0800c8af81d794be\">Подсоедините омметр между разъемом 2  форсунки и землей.</phrase></ptxt></ditemtext></ditem></diaglist></test2></test1><question>Омметр должен показывать 25 - 40 кОм;. </question><resact-grp><result button=\"ok\" comp=\"button\" highlight=\"0\"></result><action j2008use=\"0\" paperuse=\"1\" screenuse=\"0\"><ptxt>Причиной вывода кода DTC  является плохой контакт в разъеме форсунки. Исправьте  разъем в отношении качества контакта,  смотрите <xref><ref id=\"KC08117695\"><href title=\"VCC-018853-1, Проверка проводки и выводов. Постоянные неисправности\">ru-RU0900c8af80be4147#KC01111298</href></ref></xref>, а также контактного  сопротивления и окисления, смотрите <xref><ref id=\"KC08117696\"><href title=\"VCC-018853-1, Проверка проводки и выводов. Постоянные неисправности\">ru-RU0900c8af80be4147#KC01106363</href></ref></xref>.</ptxt></action><action j2008use=\"1\" paperuse=\"0\" screenuse=\"1\"><ptxt><xref><ref id=\"KC08117697\"><href title=\"Информация для поиска неисправностей\">ru-RU0900c8af80630c67#KC02333685</href></ref></xref></ptxt></action></resact-grp><resact-grp><result button=\"low\" comp=\"button\" highlight=\"0\"></result><action j2008use=\"0\" paperuse=\"1\" screenuse=\"0\"><ptxt>Проверьте провод между  разъемом 2 форсунки и ECM #A10, #A38, #A24, #A23 или #A9 (в зависимости от того, какая именно форсунка не работает)  на предмет короткого замыкания на землю, смотрите  <xref><ref id=\"KC08117698\"><href title=\"VCC-018853-1, Проверка проводки и выводов. Постоянные неисправности\">ru-RU0900c8af80be4147#KC01106352</href></ref></xref>. </ptxt></action><action j2008use=\"1\" paperuse=\"0\" screenuse=\"1\"><ptxt><xref><ref id=\"KC08117699\"><href title=\"Проверка на короткое замыкание\">ru-RU0900c8af80630c67#KC02333686</href></ref></xref></ptxt></action></resact-grp><resact-grp><result button=\"high\" comp=\"button\" highlight=\"0\"></result><action j2008use=\"1\" paperuse=\"1\" screenuse=\"1\"><ptxt><xref><ref id=\"KC08117700\"><href title=\"Проверка разъема ECM\">ru-RU0900c8af80630c67#KC02333687</href></ref></xref></ptxt></action></resact-grp></node></testgrp><testgrp id=\"KC02333685\" j2008use=\"1\" paperuse=\"0\" resumable=\"1\" screenuse=\"1\" testgrp-id=\"ebn6-1\" x=\"280\" y=\"400\"><title><phrase category=\"\" id=\"KC08117701\" phrase-urn=\"urn:x-nevis:phrase:0800c8af81d794bf\">Информация для поиска неисправностей</phrase></title><node><test1><test2><ptxt><phrase category=\"\" id=\"KC08117702\" phrase-urn=\"urn:x-nevis:phrase:0800c8af81d794c0\">Причиной вывода кода DTC является плохой контакт в  разъеме форсунки. </phrase></ptxt><diaglist><ditem><ptxt><phrase category=\"\" id=\"KC08117703\" phrase-urn=\"urn:x-nevis:phrase:0800c8af81d794c1\">Исправьте разъем в отношении качества контакта,  смотрите <xref><ref id=\"KC08117704\"><href title=\"VCC-018854-1, Проверка проводки и выводов. Неустойчивые неисправности\">ru-RU0900c8af80854dc2#KC01106832</href></ref></xref> , а также контактного сопротивления  и окисления , смотрите <xref><ref id=\"KC08117705\"><href title=\"VCC-018853-1, Проверка проводки и выводов. Постоянные неисправности\">ru-RU0900c8af80be4147#KC01106363</href></ref></xref>.</phrase></ptxt></ditem></diaglist><grate><graphic id=\"KC08117706\"><href title=\"A3700030\">0900c8af803f5451_0_0.gif</href></graphic></grate></test2></test1><question>После устранения неисправности выберите \"Continue\"  (Продолжить).</question><resact-grp><result button=\"cont\" comp=\"button\" highlight=\"0\"></result><action j2008use=\"1\" paperuse=\"0\" screenuse=\"1\"><return value=\"FAULT FOUND\"></return></action></resact-grp></node></testgrp><testgrp id=\"KC02333686\" j2008use=\"1\" paperuse=\"0\" resumable=\"1\" screenuse=\"1\" testgrp-id=\"ebn6-2\" x=\"280\" y=\"480\"><title><phrase category=\"\" id=\"KC08117707\" phrase-urn=\"urn:x-nevis:phrase:0800c8af81d794c3\">Проверка на короткое замыкание</phrase></title><node><test1><test2><diaglist><dgraphic><dgraphic1><graphic id=\"KC08117708\"><href title=\"A3000223\">0900c8af80054d6f_0_0.gif</href></graphic></dgraphic1><dgraphic2><graphic id=\"KC08117709\"><href title=\"A3000036\">0900c8af80054d47_0_0.gif</href></graphic><smarttool active=\"press\" id=\"KC08117710\" toolname=\"ODAH\"><href title=\"ODAH, \">0800c8af80070d96</href></smarttool></dgraphic2></dgraphic><ditem><ditemtext><ptxt><phrase category=\"\" id=\"KC08117711\" phrase-urn=\"urn:x-nevis:phrase:0800c8af81d794c4\">Проверьте провод между разъемом 2 форсунки и ECM #A10, #A38, #A24, #A23 или #A9 (в зависимости от того, какая именно форсунка  не работает) на предмет короткого замыкания на землю,  смотрите <xref><ref id=\"KC08117712\"><href title=\"VCC-018853-1, Проверка проводки и выводов. Постоянные неисправности\">ru-RU0900c8af80be4147#KC01106352</href></ref></xref>.</phrase></ptxt></ditemtext></ditem></diaglist><grate><graphic id=\"KC08117713\"><href title=\"A8700265\">0900c8af800570bf_0_0.gif</href></graphic></grate></test2></test1><question>После устранения неисправности выберите \"Continue\"  (Продолжить).</question><resact-grp><result button=\"cont\" comp=\"button\" highlight=\"0\"></result><action j2008use=\"1\" paperuse=\"0\" screenuse=\"1\"><return value=\"FAULT FOUND\"></return></action></resact-grp></node></testgrp><testgrp id=\"KC02333687\" j2008use=\"1\" paperuse=\"1\" resumable=\"1\" screenuse=\"1\" testgrp-id=\"ebn7\" x=\"120\" y=\"560\"><title><phrase category=\"\" id=\"KC08117714\" phrase-urn=\"urn:x-nevis:phrase:0800c8af81d794c5\">Проверка разъема ECM</phrase></title><node><test1><diaglist><dgraphic><dgraphic1><graphic id=\"KC08117715\"><href title=\"A3000037\">0900c8af80054d4b_0_0.gif</href></graphic></dgraphic1><dgraphic2><graphic id=\"KC08117716\"><href title=\"A3000242\">0900c8af80054d75_0_0.gif</href></graphic></dgraphic2><dgraphic3><graphic id=\"KC08117717\"><href title=\"A2800153\">0900c8af80054ccf_0_0.gif</href></graphic></dgraphic3></dgraphic><ditem><ptxt><phrase category=\"\" id=\"KC08117718\" phrase-urn=\"urn:x-nevis:phrase:0800c8af81d794c6\">Выключите зажигание.</phrase></ptxt></ditem><ditem><ptxt><phrase category=\"\" id=\"KC08117719\" phrase-urn=\"urn:x-nevis:phrase:0800c8af81d794c8\">Отсоедините форсунку.</phrase></ptxt></ditem><ditem><ptxt><phrase category=\"\" id=\"KC08117720\" phrase-urn=\"urn:x-nevis:phrase:0800c8af81d794c9\">Исправьте разъем ECM (сопротивление и окисление  разъема), смотрите <xref><ref id=\"KC08117721\"><href title=\"VCC-018853-1, Проверка проводки и выводов. Постоянные неисправности\">ru-RU0900c8af80be4147#KC01106363</href></ref></xref>. </phrase></ptxt></ditem><ditem><ptxt><phrase category=\"\" id=\"KC08117722\" phrase-urn=\"urn:x-nevis:phrase:0800c8af81d794ca\">Блок ECM подсоединен.</phrase></ptxt></ditem></diaglist><test2><diaglist><dgraphic><dgraphic1><graphic id=\"KC08117723\"><href title=\"A3000223\">0900c8af80054d6f_0_0.gif</href></graphic></dgraphic1><dgraphic2><graphic id=\"KC08117724\"><href title=\"A3000036\">0900c8af80054d47_0_0.gif</href></graphic><smarttool active=\"press\" id=\"KC08117725\" toolname=\"ODAH\"><href title=\"ODAH, \">0800c8af80070d96</href></smarttool></dgraphic2></dgraphic><ditem><ditemtext><ptxt><phrase category=\"\" id=\"KC08117726\" phrase-urn=\"urn:x-nevis:phrase:0800c8af81d794cb\">Подсоедините омметр между разъемом 2 форсунки и  землей.</phrase></ptxt></ditemtext></ditem></diaglist><grate><graphic id=\"KC08117727\"><href title=\"A3700030\">0900c8af803f5451_0_0.gif</href></graphic></grate></test2></test1><question>Омметр должен показывать 25 - 40 кОм;. </question><resact-grp><result button=\"ok\" comp=\"button\" highlight=\"0\"></result><action j2008use=\"0\" paperuse=\"1\" screenuse=\"0\"><ptxt>Причиной вывода кода DTC  является плохой контакт в разъеме ECM.</ptxt></action><action j2008use=\"1\" paperuse=\"0\" screenuse=\"1\"><ptxt><xref><ref id=\"KC08117728\"><href title=\"Информация для поиска неисправностей\">ru-RU0900c8af80630c67#KC02333688</href></ref></xref></ptxt></action></resact-grp><resact-grp><result button=\"notok\" comp=\"button\" highlight=\"0\"></result><action j2008use=\"0\" paperuse=\"1\" screenuse=\"0\"><ptxt>Проверьте провод между  разъемом 2 форсунки и ECM #A10, #A38, #A24, #A23 или #A9 (в зависимости от того, какая именно форсунка не работает)  на предмет размыкания, смотрите <xref><ref id=\"KC08117729\"><href title=\"VCC-018853-1, Проверка проводки и выводов. Постоянные неисправности\">ru-RU0900c8af80be4147#KC01106360</href></ref></xref>.</ptxt></action><action j2008use=\"1\" paperuse=\"0\" screenuse=\"1\"><ptxt><xref><ref id=\"KC08117730\"><href title=\"Проверка на размыкание\">ru-RU0900c8af80630c67#KC02333689</href></ref></xref></ptxt></action></resact-grp></node></testgrp><testgrp id=\"KC02333688\" j2008use=\"1\" paperuse=\"0\" resumable=\"1\" screenuse=\"1\" testgrp-id=\"ebn7-1\" x=\"280\" y=\"560\"><title><phrase category=\"\" id=\"KC08117731\" phrase-urn=\"urn:x-nevis:phrase:0800c8af81d794cd\">Информация для поиска неисправностей</phrase></title><node><test1><test2><ptxt><phrase category=\"\" id=\"KC08117732\" phrase-urn=\"urn:x-nevis:phrase:0800c8af81d794ce\">Причиной вывода кода DTC является плохой контакт в  разъеме ECM.</phrase></ptxt></test2></test1><question>Выберите \"Continue\" (Продолжить).</question><resact-grp><result button=\"cont\" comp=\"button\" highlight=\"0\"></result><action j2008use=\"1\" paperuse=\"0\" screenuse=\"1\"><return value=\"FAULT FOUND\"></return></action></resact-grp></node></testgrp><testgrp id=\"KC02333689\" j2008use=\"1\" paperuse=\"0\" resumable=\"1\" screenuse=\"1\" testgrp-id=\"ebn7-2\" x=\"280\" y=\"640\"><title><phrase category=\"\" id=\"KC08117733\" phrase-urn=\"urn:x-nevis:phrase:0800c8af81d794cf\">Проверка на размыкание</phrase></title><node><test1><test2><diaglist><dgraphic><dgraphic1><graphic id=\"KC08117734\"><href title=\"A3000223\">0900c8af80054d6f_0_0.gif</href></graphic></dgraphic1><dgraphic2><graphic id=\"KC08117735\"><href title=\"A3000036\">0900c8af80054d47_0_0.gif</href></graphic><smarttool active=\"press\" id=\"KC08117736\" toolname=\"ODAH\"><href title=\"ODAH, \">0800c8af80070d96</href></smarttool></dgraphic2></dgraphic><ditem><ditemtext><ptxt><phrase category=\"\" id=\"KC08117737\" phrase-urn=\"urn:x-nevis:phrase:0800c8af81d794d1\">Проверьте провод между разъемом 2 форсунки и ECM #A10, #A38, #A24, #A23 или #A9 (в зависимости от того, какая именно форсунка  не работает) на предмет размыкания, смотрите <xref><ref id=\"KC08117738\"><href title=\"VCC-018853-1, Проверка проводки и выводов. Постоянные неисправности\">ru-RU0900c8af80be4147#KC01106360</href></ref></xref>. </phrase></ptxt></ditemtext></ditem></diaglist><grate><graphic id=\"KC08117739\"><href title=\"A8700264\">0900c8af800570bd_0_0.gif</href></graphic></grate></test2></test1><question>После устранения неисправности выберите \"Continue\"  (Продолжить).</question><resact-grp><result button=\"cont\" comp=\"button\" highlight=\"0\"></result><action j2008use=\"1\" paperuse=\"0\" screenuse=\"1\"><return value=\"FAULT FOUND\"></return></action></resact-grp></node></testgrp><testgrp id=\"KC02333690\" j2008use=\"1\" paperuse=\"1\" resumable=\"1\" screenuse=\"1\" testgrp-id=\"ebn8\" x=\"120\" y=\"720\"><title><phrase category=\"\" id=\"KC08117740\" phrase-urn=\"urn:x-nevis:phrase:0800c8af81d794d2\">Проверка клапана EVAP</phrase></title><node><test1><diaglist></diaglist><test2><diaglist><dgraphic><dgraphic2><graphic id=\"KC08117741\"><href title=\"A0800023\">0900c8af80054332_0_0.gif</href></graphic><smarttool active=\"press\" id=\"KC08117742\" toolname=\"EM43D3\"><href title=\"EM43D3, Diagnostic test mode 3\">0800c8af80628349</href></smarttool></dgraphic2></dgraphic><ditem><ditemtext><ptxt><phrase category=\"\" id=\"KC08117743\" phrase-urn=\"urn:x-nevis:phrase:0800c8af81d794d3\">Запустите DTM 3.</phrase></ptxt><warning><ptxt><phrase category=\"\" id=\"KC08117744\" phrase-urn=\"urn:x-nevis:phrase:0800c8af81d794d4\">Последовательность DTM автоматически запустит  вентилятор охлаждения двигателя. </phrase></ptxt></warning><ptxt><phrase category=\"\" id=\"KC08117745\" phrase-urn=\"urn:x-nevis:phrase:0800c8af81d794d6\">О последовательности DTM 3 смотрите <xref><ref id=\"KC08117746\"><href title=\"VCC-021383-1, Вывод данных диагностики\">ru-RU0900c8af8042110e#KC01463050</href></ref></xref>.</phrase></ptxt></ditemtext></ditem><ditem><ptxt><phrase category=\"\" id=\"KC08117747\" phrase-urn=\"urn:x-nevis:phrase:0800c8af81d7942b\">Проверьте, нормально ли работает клапан EVAP. </phrase></ptxt></ditem></diaglist></test2></test1><question>Нормально ли работает клапан EVAP?</question><resact-grp><result button=\"yes\" comp=\"button\" highlight=\"0\"></result><action j2008use=\"1\" paperuse=\"1\" screenuse=\"1\"><ptxt><xref><ref id=\"KC08117748\"><href title=\"Пропадающая неисправность\">ru-RU0900c8af80630c67#KC02333703</href></ref></xref></ptxt></action></resact-grp><resact-grp><result button=\"no\" comp=\"button\" highlight=\"0\"></result><action j2008use=\"1\" paperuse=\"1\" screenuse=\"1\"><ptxt><xref><ref id=\"KC08117749\"><href title=\"Проверка напряжения на клапане EVAP\">ru-RU0900c8af80630c67#KC02333691</href></ref></xref></ptxt></action></resact-grp></node></testgrp><testgrp id=\"KC02333691\" j2008use=\"1\" paperuse=\"1\" resumable=\"1\" screenuse=\"1\" testgrp-id=\"ebn9\" x=\"120\" y=\"800\"><title><phrase category=\"\" id=\"KC08117750\" phrase-urn=\"urn:x-nevis:phrase:0800c8af81d7942c\">Проверка напряжения на клапане EVAP</phrase></title><node><test1><diaglist><dgraphic><dgraphic1><graphic id=\"KC08117751\"><href title=\"A3000040\">0900c8af80054d55_0_0.gif</href></graphic></dgraphic1><dgraphic2><graphic id=\"KC08117752\"><href title=\"A3000244\">0900c8af80054d7a_0_0.gif</href></graphic></dgraphic2></dgraphic><ditem><hint><ptxt><phrase category=\"\" id=\"KC08117753\" phrase-urn=\"urn:x-nevis:phrase:0800c8af81d7942e\">Для того, чтобы добраться до клапана EVAP,  необходимо отсоединить следующие компоненты:</phrase></ptxt><ptxt><phrase category=\"\" id=\"KC08117754\" phrase-urn=\"urn:x-nevis:phrase:0800c8af81d7942f\">Клапан от кронштейна.</phrase></ptxt><ptxt><phrase category=\"\" id=\"KC08117755\" phrase-urn=\"urn:x-nevis:phrase:0800c8af81d79430\">Звукоизоляцию от клапана.</phrase></ptxt><ptxt><phrase category=\"\" id=\"KC08117756\" phrase-urn=\"urn:x-nevis:phrase:0800c8af81d79431\">После обнаружении неисправности установите  клапан, шланги и звукоизоляцию на место при помощи  плоскогубцев 981 4215, следует также установить новый хомут  шланга.</phrase></ptxt></hint></ditem><ditem><ptxt><phrase category=\"\" id=\"KC08117757\" phrase-urn=\"urn:x-nevis:phrase:0800c8af81d79433\">Выключите зажигание.</phrase></ptxt></ditem><ditem><ptxt><phrase category=\"\" id=\"KC08117758\" phrase-urn=\"urn:x-nevis:phrase:0800c8af81d79434\">Отсоедините клапан EVAP.</phrase></ptxt></ditem><ditem><ptxt><phrase category=\"\" id=\"KC08117759\" phrase-urn=\"urn:x-nevis:phrase:0800c8af81d79435\">Включите зажигание.</phrase></ptxt></ditem></diaglist><test2><diaglist><dgraphic><dgraphic1><graphic id=\"KC08117760\"><href title=\"A3000223\">0900c8af80054d6f_0_0.gif</href></graphic></dgraphic1><dgraphic2><graphic id=\"KC08117761\"><href title=\"A3000031\">0900c8af80054d45_0_0.gif</href></graphic><smarttool id=\"KC08117762\" toolname=\"VDCD40\"><href title=\"VDCD40, voltage DC digital meter 40 volt\">0800c8af80114135</href></smarttool></dgraphic2></dgraphic><ditem><ditemtext><ptxt><phrase category=\"\" id=\"KC08117763\" phrase-urn=\"urn:x-nevis:phrase:0800c8af81d79437\">Подсоедините вольтметр между  разъемом 1 клапана EVAP и землей.</phrase></ptxt></ditemtext></ditem></diaglist></test2></test1><question>Вольтметр должен показывать напряжение  аккумулятора. </question><resact-grp><result button=\"ok\" comp=\"button\" highlight=\"0\"></result><action j2008use=\"1\" paperuse=\"1\" screenuse=\"1\"><ptxt><xref><ref id=\"KC08117764\"><href title=\"Проверка клапана EVAP\">ru-RU0900c8af80630c67#KC02333693</href></ref></xref></ptxt></action></resact-grp><resact-grp><result button=\"notok\" comp=\"button\" highlight=\"0\"></result><action j2008use=\"0\" paperuse=\"1\" screenuse=\"0\"><ptxt>Проверьте провод между  разъемом 1 клапана EVAP и главным реле (2/32) на предмет  размыкания, смотрите  <xref><ref id=\"KC08117765\"><href title=\"VCC-018853-1, Проверка проводки и выводов. Постоянные неисправности\">ru-RU0900c8af80be4147#KC01106360</href></ref></xref>. </ptxt></action><action j2008use=\"1\" paperuse=\"0\" screenuse=\"1\"><ptxt><xref><ref id=\"KC08117766\"><href title=\"Проверка на размыкание\">ru-RU0900c8af80630c67#KC02333692</href></ref></xref></ptxt></action></resact-grp></node></testgrp><testgrp id=\"KC02333692\" j2008use=\"1\" paperuse=\"0\" resumable=\"1\" screenuse=\"1\" testgrp-id=\"ebn9-1\" x=\"280\" y=\"800\"><title><phrase category=\"\" id=\"KC08117767\" phrase-urn=\"urn:x-nevis:phrase:0800c8af81d79438\">Проверка на размыкание</phrase></title><node><test1><test2><diaglist><dgraphic><dgraphic1><graphic id=\"KC08117768\"><href title=\"A3000223\">0900c8af80054d6f_0_0.gif</href></graphic></dgraphic1><dgraphic2><graphic id=\"KC08117769\"><href title=\"A3000036\">0900c8af80054d47_0_0.gif</href></graphic><smarttool active=\"press\" id=\"KC08117770\" toolname=\"ODAH\"><href title=\"ODAH, \">0800c8af80070d96</href></smarttool></dgraphic2></dgraphic><ditem><ditemtext><ptxt><phrase category=\"\" id=\"KC08117771\" phrase-urn=\"urn:x-nevis:phrase:0800c8af81d79439\">Проверьте провод между разъемом 1 клапана EVAP и  главным реле (2/32) на предмет размыкания, смотрите  <xref><ref id=\"KC08117772\"><href title=\"VCC-018853-1, Проверка проводки и выводов. Постоянные неисправности\">ru-RU0900c8af80be4147#KC01106360</href></ref></xref>.</phrase></ptxt></ditemtext></ditem></diaglist><grate><graphic id=\"KC08117773\"><href title=\"A8700264\">0900c8af800570bd_0_0.gif</href></graphic></grate></test2></test1><question>После устранения неисправности выберите \"Continue\"  (Продолжить).</question><resact-grp><result button=\"cont\" comp=\"button\" highlight=\"0\"></result><action j2008use=\"1\" paperuse=\"0\" screenuse=\"1\"><return value=\"FAULT FOUND\"></return></action></resact-grp></node></testgrp><testgrp id=\"KC02333693\" j2008use=\"1\" paperuse=\"1\" resumable=\"1\" screenuse=\"1\" testgrp-id=\"ebn10\" x=\"120\" y=\"880\"><title><phrase category=\"\" id=\"KC08117774\" phrase-urn=\"urn:x-nevis:phrase:0800c8af81d7943a\">Проверка клапана EVAP</phrase></title><node><test1><diaglist><dgraphic><dgraphic1><graphic id=\"KC08117775\"><href title=\"A3000037\">0900c8af80054d4b_0_0.gif</href></graphic></dgraphic1><dgraphic2><graphic id=\"KC08117776\"><href title=\"A3000242\">0900c8af80054d75_0_0.gif</href></graphic></dgraphic2></dgraphic><ditem><ptxt><phrase category=\"\" id=\"KC08117777\" phrase-urn=\"urn:x-nevis:phrase:0800c8af81d7943c\">Выключите зажигание.</phrase></ptxt></ditem><ditem><ptxt><phrase category=\"\" id=\"KC08117778\" phrase-urn=\"urn:x-nevis:phrase:0800c8af81d7943d\">Клапан EVAP отсоединен.</phrase></ptxt></ditem></diaglist><test2><diaglist><dgraphic><dgraphic1><graphic id=\"KC08117779\"><href title=\"A3000228\">0900c8af80128106_0_0.gif</href></graphic></dgraphic1><dgraphic2><graphic id=\"KC08117780\"><href title=\"A3000036\">0900c8af80054d47_0_0.gif</href></graphic><smarttool id=\"KC08117781\" toolname=\"ODA\"><href title=\"ODA, Ohm digital meter autorange\">0800c8af80070e43</href></smarttool></dgraphic2></dgraphic><ditem><ditemtext><ptxt><phrase category=\"\" id=\"KC08117782\" phrase-urn=\"urn:x-nevis:phrase:0800c8af81d7943e\">Подсоедините омметр между разъемами 1  и 2 клапана EVAP.</phrase></ptxt></ditemtext></ditem></diaglist></test2></test1><question>Омметр должен показывать приблизительно 26 Ω при +20°C .</question><resact-grp><result button=\"ok\" comp=\"button\" highlight=\"0\"></result><action j2008use=\"1\" paperuse=\"1\" screenuse=\"1\"><ptxt><xref><ref id=\"KC08117783\"><href title=\"Проверка сигнального провода\">ru-RU0900c8af80630c67#KC02333695</href></ref></xref></ptxt></action></resact-grp><resact-grp><result button=\"notok\" comp=\"button\" highlight=\"0\"></result><action j2008use=\"0\" paperuse=\"1\" screenuse=\"0\"><ptxt>Проверьте работу с новым  клапаном EVAP.</ptxt></action><action j2008use=\"1\" paperuse=\"0\" screenuse=\"1\"><ptxt><xref><ref id=\"KC08117784\"><href title=\"Замена компонента\">ru-RU0900c8af80630c67#KC02333694</href></ref></xref></ptxt></action></resact-grp></node></testgrp><testgrp id=\"KC02333694\" j2008use=\"1\" paperuse=\"0\" resumable=\"1\" screenuse=\"1\" testgrp-id=\"ebn10-1\" x=\"280\" y=\"880\"><title><phrase category=\"\" id=\"KC08117785\" phrase-urn=\"urn:x-nevis:phrase:0800c8af81d79440\">Замена компонента</phrase></title><node><test1><test2><diaglist><ditem><ptxt><phrase category=\"\" id=\"KC08117786\" phrase-urn=\"urn:x-nevis:phrase:0800c8af81d79441\">Проверьте работу с новым клапаном EVAP.</phrase></ptxt></ditem></diaglist><grate><graphic id=\"KC08117787\"><href title=\"A2300532\">0900c8af8012040d_0_0.gif</href></graphic></grate></test2></test1><question>После устранения неисправности выберите \"Continue\"  (Продолжить).</question><resact-grp><result button=\"cont\" comp=\"button\" highlight=\"0\"></result><action j2008use=\"1\" paperuse=\"0\" screenuse=\"1\"><return value=\"FAULT FOUND\"></return></action></resact-grp></node></testgrp><testgrp id=\"KC02333695\" j2008use=\"1\" paperuse=\"1\" resumable=\"1\" screenuse=\"1\" testgrp-id=\"ebn11\" x=\"120\" y=\"960\"><title><phrase category=\"\" id=\"KC08117788\" phrase-urn=\"urn:x-nevis:phrase:0800c8af81d79442\">Проверка сигнального провода</phrase></title><node><test1><diaglist><dgraphic><dgraphic1><graphic id=\"KC08117789\"><href title=\"A3000040\">0900c8af80054d55_0_0.gif</href></graphic></dgraphic1><dgraphic2><graphic id=\"KC08117790\"><href title=\"A3000242\">0900c8af80054d75_0_0.gif</href></graphic></dgraphic2></dgraphic><ditem><ptxt><phrase category=\"\" id=\"KC08117791\" phrase-urn=\"urn:x-nevis:phrase:0800c8af81d79443\">Включите зажигание.</phrase></ptxt></ditem><ditem><ptxt><phrase category=\"\" id=\"KC08117792\" phrase-urn=\"urn:x-nevis:phrase:0800c8af81d79445\">Клапан EVAP отсоединен.</phrase></ptxt></ditem></diaglist><test2><diaglist><dgraphic><dgraphic1><graphic id=\"KC08117793\"><href title=\"A3000223\">0900c8af80054d6f_0_0.gif</href></graphic></dgraphic1><dgraphic2><graphic id=\"KC08117794\"><href title=\"A3000031\">0900c8af80054d45_0_0.gif</href></graphic><smarttool id=\"KC08117795\" toolname=\"VDCD40\"><href title=\"VDCD40, voltage DC digital meter 40 volt\">0800c8af80114135</href></smarttool></dgraphic2></dgraphic><ditem><ditemtext><ptxt><phrase category=\"\" id=\"KC08117796\" phrase-urn=\"urn:x-nevis:phrase:0800c8af81d79446\">Подсоедините вольтметр между  разъемом 2 клапана EVAP и землей.</phrase></ptxt></ditemtext></ditem></diaglist></test2></test1><question>Вольтметр должен показывать приблизительно 0  В. </question><resact-grp><result button=\"ok\" comp=\"button\" highlight=\"0\"></result><action j2008use=\"1\" paperuse=\"1\" screenuse=\"1\"><ptxt><xref><ref id=\"KC08117797\"><href title=\"Проверка сопротивления между сигнальным &#xA;проводом и землей&#xA;\">ru-RU0900c8af80630c67#KC02333697</href></ref></xref></ptxt></action></resact-grp><resact-grp><result button=\"notok\" comp=\"button\" highlight=\"0\"></result><action j2008use=\"0\" paperuse=\"1\" screenuse=\"0\"><ptxt>Проверьте провод между  разъемом 2 клапана EVAP и ECM #A39 на предмет короткого замыкания на источник питания, смотрите <xref><ref id=\"KC08117798\"><href title=\"VCC-018853-1, Проверка проводки и выводов. Постоянные неисправности\">ru-RU0900c8af80be4147#KC01106854</href></ref></xref>.</ptxt></action><action j2008use=\"1\" paperuse=\"0\" screenuse=\"1\"><ptxt><xref><ref id=\"KC08117799\"><href title=\"Проверка на короткое замыкание\">ru-RU0900c8af80630c67#KC02333696</href></ref></xref></ptxt></action></resact-grp></node></testgrp><testgrp id=\"KC02333696\" j2008use=\"1\" paperuse=\"0\" resumable=\"1\" screenuse=\"1\" testgrp-id=\"ebn11-1\" x=\"280\" y=\"960\"><title><phrase category=\"\" id=\"KC08117800\" phrase-urn=\"urn:x-nevis:phrase:0800c8af81d79447\">Проверка на короткое замыкание</phrase></title><node><test1><test2><diaglist><dgraphic><dgraphic1><graphic id=\"KC08117801\"><href title=\"A3000223\">0900c8af80054d6f_0_0.gif</href></graphic></dgraphic1><dgraphic2><graphic id=\"KC08117802\"><href title=\"A3000036\">0900c8af80054d47_0_0.gif</href></graphic><smarttool active=\"press\" id=\"KC08117803\" toolname=\"ODAH\"><href title=\"ODAH, \">0800c8af80070d96</href></smarttool></dgraphic2></dgraphic><ditem><ditemtext><ptxt><phrase category=\"\" id=\"KC08117804\" phrase-urn=\"urn:x-nevis:phrase:0800c8af81d79448\">Проверьте провод между разъемом 2 клапана EVAP и ECM #A39 на  предмет короткого замыкания на источник питания,  смотрите <xref><ref id=\"KC08117805\"><href title=\"VCC-018853-1, Проверка проводки и выводов. Постоянные неисправности\">ru-RU0900c8af80be4147#KC01106854</href></ref></xref>.</phrase></ptxt></ditemtext></ditem></diaglist><grate><graphic id=\"KC08117806\"><href title=\"A8700266\">0900c8af800570c2_0_0.gif</href></graphic></grate></test2></test1><question>После устранения неисправности выберите \"Continue\"  (Продолжить).</question><resact-grp><result button=\"cont\" comp=\"button\" highlight=\"0\"></result><action j2008use=\"1\" paperuse=\"0\" screenuse=\"1\"><return value=\"FAULT FOUND\"></return></action></resact-grp></node></testgrp><testgrp id=\"KC02333697\" j2008use=\"1\" paperuse=\"1\" resumable=\"1\" screenuse=\"1\" testgrp-id=\"ebn12\" x=\"120\" y=\"1040\"><title><phrase category=\"\" id=\"KC08117807\" phrase-urn=\"urn:x-nevis:phrase:0800c8af81d7944a\">Проверка сопротивления между сигнальным  проводом и землей </phrase></title><node><test1><diaglist><dgraphic><dgraphic1><graphic id=\"KC08117808\"><href title=\"A3000037\">0900c8af80054d4b_0_0.gif</href></graphic></dgraphic1><dgraphic2><graphic id=\"KC08117809\"><href title=\"A3000242\">0900c8af80054d75_0_0.gif</href></graphic></dgraphic2></dgraphic><ditem><ptxt><phrase category=\"\" id=\"KC08117810\" phrase-urn=\"urn:x-nevis:phrase:0800c8af81d7944b\">Выключите зажигание.</phrase></ptxt></ditem><ditem><ptxt><phrase category=\"\" id=\"KC08117811\" phrase-urn=\"urn:x-nevis:phrase:0800c8af81d7944d\">Подождите примерно 150 сек.</phrase></ptxt></ditem><ditem><ptxt><phrase category=\"\" id=\"KC08117812\" phrase-urn=\"urn:x-nevis:phrase:0800c8af81d7944e\">Клапан EVAP отсоединен.</phrase></ptxt></ditem></diaglist><test2><diaglist><dgraphic><dgraphic1><graphic id=\"KC08117813\"><href title=\"A3000223\">0900c8af80054d6f_0_0.gif</href></graphic></dgraphic1><dgraphic2><graphic id=\"KC08117814\"><href title=\"A3000036\">0900c8af80054d47_0_0.gif</href></graphic><smarttool id=\"KC08117815\" toolname=\"ODA\"><href title=\"ODA, Ohm digital meter autorange\">0800c8af80070e43</href></smarttool></dgraphic2></dgraphic><ditem><ditemtext><ptxt><phrase category=\"\" id=\"KC08117816\" phrase-urn=\"urn:x-nevis:phrase:0800c8af81d7944f\">Подсоедините омметр между разъемом 2  клапана EVAP и землей.</phrase></ptxt></ditemtext></ditem></diaglist></test2></test1><question>Омметр должен показывать 25 - 40 кОм;. </question><resact-grp><result button=\"ok\" comp=\"button\" highlight=\"0\"></result><action j2008use=\"0\" paperuse=\"1\" screenuse=\"0\"><ptxt>Причиной вывода кода DTC  является плохой контакт в разъеме клапана EVAP. Исправьте  разъем в отношении качества  контактов, смотрите <xref><ref id=\"KC08117817\"><href title=\"VCC-018853-1, Проверка проводки и выводов. Постоянные неисправности\">ru-RU0900c8af80be4147#KC01111298</href></ref></xref>, а также контактного  сопротивления и окисления , смотрите <xref><ref id=\"KC08117818\"><href title=\"VCC-018853-1, Проверка проводки и выводов. Постоянные неисправности\">ru-RU0900c8af80be4147#KC01106363</href></ref></xref>.</ptxt></action><action j2008use=\"1\" paperuse=\"0\" screenuse=\"1\"><ptxt><xref><ref id=\"KC08117819\"><href title=\"Информация для поиска неисправностей\">ru-RU0900c8af80630c67#KC02333698</href></ref></xref></ptxt></action></resact-grp><resact-grp><result button=\"low\" comp=\"button\" highlight=\"0\"></result><action j2008use=\"0\" paperuse=\"1\" screenuse=\"0\"><ptxt>Проверьте провод между  разъемом 2 клапана EVAP и ECM #A39 на предмет короткого замыкания на землю, смотрите <xref><ref id=\"KC08117820\"><href title=\"VCC-018853-1, Проверка проводки и выводов. Постоянные неисправности\">ru-RU0900c8af80be4147#KC01106352</href></ref></xref>. </ptxt></action><action j2008use=\"1\" paperuse=\"0\" screenuse=\"1\"><ptxt><xref><ref id=\"KC08117821\"><href title=\"Проверка на короткое замыкание\">ru-RU0900c8af80630c67#KC02333699</href></ref></xref></ptxt></action></resact-grp><resact-grp><result button=\"high\" comp=\"button\" highlight=\"0\">Если омметр показывает бесконечно  большое сопротивление:</result><action j2008use=\"1\" paperuse=\"1\" screenuse=\"1\"><ptxt>Проверьте  разъем ECM, смотрите  <xref><ref id=\"KC08117822\"><href title=\"Проверка разъема ECM\">ru-RU0900c8af80630c67#KC02333700</href></ref></xref>.</ptxt></action></resact-grp></node></testgrp><testgrp id=\"KC02333698\" j2008use=\"1\" paperuse=\"0\" resumable=\"1\" screenuse=\"1\" testgrp-id=\"ebn12-1\" x=\"280\" y=\"1040\"><title><phrase category=\"\" id=\"KC08117823\" phrase-urn=\"urn:x-nevis:phrase:0800c8af81d79450\">Информация для поиска неисправностей</phrase></title><node><test1><test2><ptxt><phrase category=\"\" id=\"KC08117824\" phrase-urn=\"urn:x-nevis:phrase:0800c8af81d79452\">Причиной вывода кода DTC является плохой контакт в  разъеме клапана EVAP. </phrase></ptxt><diaglist><ditem><ptxt><phrase category=\"\" id=\"KC08117825\" phrase-urn=\"urn:x-nevis:phrase:0800c8af81d79453\">Исправьте разъем в отношении качества контактов,  смотрите <xref><ref id=\"KC08117826\"><href title=\"VCC-018854-1, Проверка проводки и выводов. Неустойчивые неисправности\">ru-RU0900c8af80854dc2#KC01106832</href></ref></xref>, а также контактного сопротивления  и окисления , смотрите <xref><ref id=\"KC08117827\"><href title=\"VCC-018853-1, Проверка проводки и выводов. Постоянные неисправности\">ru-RU0900c8af80be4147#KC01106363</href></ref></xref>.</phrase></ptxt></ditem></diaglist><grate><graphic id=\"KC08117828\"><href title=\"A3700030\">0900c8af803f5451_0_0.gif</href></graphic></grate></test2></test1><question>После устранения неисправности выберите \"Continue\"  (Продолжить).</question><resact-grp><result button=\"cont\" comp=\"button\" highlight=\"0\"></result><action j2008use=\"1\" paperuse=\"0\" screenuse=\"1\"><return value=\"FAULT FOUND\"></return></action></resact-grp></node></testgrp><testgrp id=\"KC02333699\" j2008use=\"1\" paperuse=\"0\" resumable=\"1\" screenuse=\"1\" testgrp-id=\"ebn12-2\" x=\"280\" y=\"1120\"><title><phrase category=\"\" id=\"KC08117829\" phrase-urn=\"urn:x-nevis:phrase:0800c8af81d79454\">Проверка на короткое замыкание</phrase></title><node><test1><test2><diaglist><dgraphic><dgraphic1><graphic id=\"KC08117830\"><href title=\"A3000223\">0900c8af80054d6f_0_0.gif</href></graphic></dgraphic1><dgraphic2><graphic id=\"KC08117831\"><href title=\"A3000036\">0900c8af80054d47_0_0.gif</href></graphic><smarttool active=\"press\" id=\"KC08117832\" toolname=\"ODAH\"><href title=\"ODAH, \">0800c8af80070d96</href></smarttool></dgraphic2></dgraphic><ditem><ditemtext><ptxt><phrase category=\"\" id=\"KC08117833\" phrase-urn=\"urn:x-nevis:phrase:0800c8af81d79456\">Проверьте провод между разъемом 2 клапана EVAP и ECM #A39 на  предмет короткого замыкания на землю, смотрите  <xref><ref id=\"KC08117834\"><href title=\"VCC-018853-1, Проверка проводки и выводов. Постоянные неисправности\">ru-RU0900c8af80be4147#KC01106352</href></ref></xref>.</phrase></ptxt></ditemtext></ditem></diaglist><grate><graphic id=\"KC08117835\"><href title=\"A8700265\">0900c8af800570bf_0_0.gif</href></graphic></grate></test2></test1><question>После устранения неисправности выберите \"Continue\"  (Продолжить).</question><resact-grp><result button=\"cont\" comp=\"button\" highlight=\"0\"></result><action j2008use=\"1\" paperuse=\"0\" screenuse=\"1\"><return value=\"FAULT FOUND\"></return></action></resact-grp></node></testgrp><testgrp id=\"KC02333700\" j2008use=\"1\" paperuse=\"1\" resumable=\"1\" screenuse=\"1\" testgrp-id=\"ebn13\" x=\"120\" y=\"1200\"><title><phrase category=\"\" id=\"KC08117836\" phrase-urn=\"urn:x-nevis:phrase:0800c8af81d79457\">Проверка разъема ECM</phrase></title><node><test1><diaglist><dgraphic><dgraphic1><graphic id=\"KC08117837\"><href title=\"A3000037\">0900c8af80054d4b_0_0.gif</href></graphic></dgraphic1><dgraphic2><graphic id=\"KC08117838\"><href title=\"A3000242\">0900c8af80054d75_0_0.gif</href></graphic></dgraphic2><dgraphic3><graphic id=\"KC08117839\"><href title=\"A2800153\">0900c8af80054ccf_0_0.gif</href></graphic></dgraphic3></dgraphic><ditem><ptxt><phrase category=\"\" id=\"KC08117840\" phrase-urn=\"urn:x-nevis:phrase:0800c8af81d79458\">Выключите зажигание.</phrase></ptxt></ditem><ditem><ptxt><phrase category=\"\" id=\"KC08117841\" phrase-urn=\"urn:x-nevis:phrase:0800c8af81d79459\">Клапан EVAP отсоединен.</phrase></ptxt></ditem><ditem><ptxt><phrase category=\"\" id=\"KC08117842\" phrase-urn=\"urn:x-nevis:phrase:0800c8af81d7945b\">Исправьте разъем ECM в отношении контактного сопротивления и окисления, смотрите  <xref><ref id=\"KC08117843\"><href title=\"VCC-018853-1, Проверка проводки и выводов. Постоянные неисправности\">ru-RU0900c8af80be4147#KC01106363</href></ref></xref>. </phrase></ptxt></ditem><ditem><ptxt><phrase category=\"\" id=\"KC08117844\" phrase-urn=\"urn:x-nevis:phrase:0800c8af81d7945c\">Блок ECM подсоединен.</phrase></ptxt></ditem></diaglist><test2><diaglist><dgraphic><dgraphic1><graphic id=\"KC08117845\"><href title=\"A3000223\">0900c8af80054d6f_0_0.gif</href></graphic></dgraphic1><dgraphic2><graphic id=\"KC08117846\"><href title=\"A3000036\">0900c8af80054d47_0_0.gif</href></graphic><smarttool active=\"press\" id=\"KC08117847\" toolname=\"ODAH\"><href title=\"ODAH, \">0800c8af80070d96</href></smarttool></dgraphic2></dgraphic><ditem><ditemtext><ptxt><phrase category=\"\" id=\"KC08117848\" phrase-urn=\"urn:x-nevis:phrase:0800c8af81d7945d\">Подсоедините омметр между разъемом 2 клапана EVAP и  землей.</phrase></ptxt></ditemtext></ditem></diaglist><grate><graphic id=\"KC08117849\"><href title=\"A3700030\">0900c8af803f5451_0_0.gif</href></graphic></grate></test2></test1><question>Омметр должен показывать 25 - 40 кОм;. </question><resact-grp><result button=\"ok\" comp=\"button\" highlight=\"0\"></result><action j2008use=\"0\" paperuse=\"1\" screenuse=\"0\"><ptxt>Причиной вывода кода DTC  является плохой контакт в разъеме ECM.</ptxt></action><action j2008use=\"1\" paperuse=\"0\" screenuse=\"1\"><ptxt><xref><ref id=\"KC08117850\"><href title=\"Информация для поиска неисправностей\">ru-RU0900c8af80630c67#KC02333701</href></ref></xref></ptxt></action></resact-grp><resact-grp><result button=\"notok\" comp=\"button\" highlight=\"0\"></result><action j2008use=\"0\" paperuse=\"1\" screenuse=\"0\"><ptxt>Проверьте провод между  разъемом 2 клапана EVAP и ECM #A39 на предмет размыкания, смотрите  <xref><ref id=\"KC08117851\"><href title=\"VCC-018853-1, Проверка проводки и выводов. Постоянные неисправности\">ru-RU0900c8af80be4147#KC01106360</href></ref></xref>.</ptxt></action><action j2008use=\"1\" paperuse=\"0\" screenuse=\"1\"><ptxt><xref><ref id=\"KC08117852\"><href title=\"Проверка на размыкание\">ru-RU0900c8af80630c67#KC02333702</href></ref></xref></ptxt></action></resact-grp></node></testgrp><testgrp id=\"KC02333701\" j2008use=\"1\" paperuse=\"0\" resumable=\"1\" screenuse=\"1\" testgrp-id=\"ebn13-1\" x=\"280\" y=\"1200\"><title><phrase category=\"\" id=\"KC08117853\" phrase-urn=\"urn:x-nevis:phrase:0800c8af81d7945f\">Информация для поиска неисправностей</phrase></title><node><test1><test2><ptxt><phrase category=\"\" id=\"KC08117854\" phrase-urn=\"urn:x-nevis:phrase:0800c8af81d79460\">Причиной вывода кода DTC является плохой контакт в  разъеме ECM.</phrase></ptxt></test2></test1><question>Выберите \"Continue\" (Продолжить).</question><resact-grp><result button=\"cont\" comp=\"button\" highlight=\"0\"></result><action j2008use=\"1\" paperuse=\"0\" screenuse=\"1\"><return value=\"FAULT FOUND\"></return></action></resact-grp></node></testgrp><testgrp id=\"KC02333702\" j2008use=\"1\" paperuse=\"0\" resumable=\"1\" screenuse=\"1\" testgrp-id=\"ebn13-2\" x=\"280\" y=\"1280\"><title><phrase category=\"\" id=\"KC08117855\" phrase-urn=\"urn:x-nevis:phrase:0800c8af81d79461\">Проверка на размыкание</phrase></title><node><test1><test2><diaglist><dgraphic><dgraphic1><graphic id=\"KC08117856\"><href title=\"A3000223\">0900c8af80054d6f_0_0.gif</href></graphic></dgraphic1><dgraphic2><graphic id=\"KC08117857\"><href title=\"A3000036\">0900c8af80054d47_0_0.gif</href></graphic><smarttool active=\"press\" id=\"KC08117858\" toolname=\"ODAH\"><href title=\"ODAH, \">0800c8af80070d96</href></smarttool></dgraphic2></dgraphic><ditem><ditemtext><ptxt><phrase category=\"\" id=\"KC08117859\" phrase-urn=\"urn:x-nevis:phrase:0800c8af81d79462\">Проверьте провод между разъемом 2 клапана EVAP и ECM #A39 на  предмет размыкания, смотрите <xref><ref id=\"KC08117860\"><href title=\"VCC-018853-1, Проверка проводки и выводов. Постоянные неисправности\">ru-RU0900c8af80be4147#KC01106360</href></ref></xref>. </phrase></ptxt></ditemtext></ditem></diaglist><grate><graphic id=\"KC08117861\"><href title=\"A8700264\">0900c8af800570bd_0_0.gif</href></graphic></grate></test2></test1><question>После устранения неисправности выберите \"Continue\"  (Продолжить).</question><resact-grp><result button=\"cont\" comp=\"button\" highlight=\"0\"></result><action j2008use=\"1\" paperuse=\"0\" screenuse=\"1\"><return value=\"FAULT FOUND\"></return></action></resact-grp></node></testgrp><testgrp id=\"KC02333703\" j2008use=\"1\" paperuse=\"1\" resumable=\"1\" screenuse=\"1\" testgrp-id=\"ebn14\" x=\"120\" y=\"1360\"><title><phrase category=\"\" id=\"KC08117862\" phrase-urn=\"urn:x-nevis:phrase:0800c8af81d79464\">Пропадающая неисправность</phrase></title><iecalloutnode><diagcallout><xref><ref id=\"KC08117863\"><href title=\"VCC-021402-1, Ошибочный сигнал. Пропадающая неисправность\">ru-RU0900c8af80631f07#KC02182527</href></ref></xref></diagcallout><test1><test2></test2></test1><question></question><resact-grp><result comp=\"string\" highlight=\"0\" op=\"eq\" return=\"FAULT FOUND\"></result><action j2008use=\"1\" paperuse=\"0\" screenuse=\"1\"><return value=\"FAULT FOUND\"></return></action></resact-grp></iecalloutnode></testgrp></diagnostic></servinfosub>","description_plain":"Ошибочный сигнал\n5-3-1 Группа A силового каскада\nПроверка форсунок\nЗапустите DTM 3.\nПоследовательность DTM автоматически запустит вентилятор охлаждения двигателя.\nО последовательности DTM 3 смотрите ru-RU0900c8af8042110e#KC01463050.\nДля нормальной работы DTM 3 должны быть подсоединены три форсунки. Таким образом тест может выполняться несколько раз для разных форсунок.\nПроверьте, хорошо ли работают форсунки.\nНормально ли работают форсунки?\nru-RU0900c8af80630c67#KC02333690\nru-RU0900c8af80630c67#KC02333678\nПроверка подачи питания на форсунки\nВыключите зажигание.\nОтключите соответствующую форсунку.\nВключите зажигание.\nПодсоедините вольтметр между разъемом 1 форсунки и землей.\nВольтметр должен показывать напряжение аккумулятора.\nru-RU0900c8af80630c67#KC02333680\nПроверьте провод между разъемом 3 главного реле (2/32) и разъемом 1 форсунки на предмет размыкания, смотрите ru-RU0900c8af80be4147#KC01106360.\nru-RU0900c8af80630c67#KC02333679\nПроверка на размыкание\nПосле устранения неисправности выберите \"Continue\" (Продолжить).\nПроверьте форсунку\nОтсоедините форсунку.\nПодсоедините омметр между разъемами 1 и 2 форсунки.\nОмметр должен показывать приблизительно 14,5 Ω при +20°C .\nru-RU0900c8af80630c67#KC02333682\nПроверьте работу с новой форсункой.\nru-RU0900c8af80630c67#KC02333681\nЗамена компонента\nПроверка сигнального провода\nПодсоедините вольтметр между разъемом 2 форсунки и землей.\nВольтметр должен показывать приблизительно 0 В.\nru-RU0900c8af80630c67#KC02333684\nПроверьте провод между разъемом 2 форсунки и ECM #A10, #A38, #A24, #A23 или #A9 (в зависимости от того, какая именно форсунка не работает) на предмет короткого замыкания на источник питания, смотрите ru-RU0900c8af80be4147#KC01106854.\nru-RU0900c8af80630c67#KC02333683\nПроверка на короткое замыкание\nПроверка сопротивления между сигнальным проводом и землей\nПодождите примерно 150 сек.\nПодсоедините омметр между разъемом 2 форсунки и землей.\nОмметр должен показывать 25 - 40 кОм;.\nПричиной вывода кода DTC является плохой контакт в разъеме форсунки. Исправьте разъем в отношении качества контакта, смотрите ru-RU0900c8af80be4147#KC01111298, а также контактного сопротивления и окисления, смотрите ru-RU0900c8af80be4147#KC01106363.\nru-RU0900c8af80630c67#KC02333685\nПроверьте провод между разъемом 2 форсунки и ECM #A10, #A38, #A24, #A23 или #A9 (в зависимости от того, какая именно форсунка не работает) на предмет короткого замыкания на землю, смотрите ru-RU0900c8af80be4147#KC01106352.\nru-RU0900c8af80630c67#KC02333686\nru-RU0900c8af80630c67#KC02333687\nИнформация для поиска неисправностей\nПричиной вывода кода DTC является плохой контакт в разъеме форсунки.\nИсправьте разъем в отношении качества контакта, смотрите ru-RU0900c8af80854dc2#KC01106832 , а также контактного сопротивления и окисления , смотрите ru-RU0900c8af80be4147#KC01106363.\nПроверка разъема ECM\nИсправьте разъем ECM (сопротивление и окисление разъема), смотрите ru-RU0900c8af80be4147#KC01106363.\nБлок ECM подсоединен.\nПричиной вывода кода DTC является плохой контакт в разъеме ECM.\nru-RU0900c8af80630c67#KC02333688\nПроверьте провод между разъемом 2 форсунки и ECM #A10, #A38, #A24, #A23 или #A9 (в зависимости от того, какая именно форсунка не работает) на предмет размыкания, смотрите ru-RU0900c8af80be4147#KC01106360.\nru-RU0900c8af80630c67#KC02333689\nВыберите \"Continue\" (Продолжить).\nПроверка клапана EVAP\nПроверьте, нормально ли работает клапан EVAP.\nНормально ли работает клапан EVAP?\nru-RU0900c8af80630c67#KC02333703\nru-RU0900c8af80630c67#KC02333691\nПроверка напряжения на клапане EVAP\nДля того, чтобы добраться до клапана EVAP, необходимо отсоединить следующие компоненты:\nКлапан от кронштейна.\nЗвукоизоляцию от клапана.\nПосле обнаружении неисправности установите клапан, шланги и звукоизоляцию на место при помощи плоскогубцев 981 4215, следует также установить новый хомут шланга.\nОтсоедините клапан EVAP.\nПодсоедините вольтметр между разъемом 1 клапана EVAP и землей.\nru-RU0900c8af80630c67#KC02333693\nПроверьте провод между разъемом 1 клапана EVAP и главным реле (2/32) на предмет размыкания, смотрите ru-RU0900c8af80be4147#KC01106360.\nru-RU0900c8af80630c67#KC02333692\nКлапан EVAP отсоединен.\nПодсоедините омметр между разъемами 1 и 2 клапана EVAP.\nОмметр должен показывать приблизительно 26 Ω при +20°C .\nru-RU0900c8af80630c67#KC02333695\nПроверьте работу с новым клапаном EVAP.\nru-RU0900c8af80630c67#KC02333694\nПодсоедините вольтметр между разъемом 2 клапана EVAP и землей.\nru-RU0900c8af80630c67#KC02333697\nПроверьте провод между разъемом 2 клапана EVAP и ECM #A39 на предмет короткого замыкания на источник питания, смотрите ru-RU0900c8af80be4147#KC01106854.\nru-RU0900c8af80630c67#KC02333696\nПодсоедините омметр между разъемом 2 клапана EVAP и землей.\nПричиной вывода кода DTC является плохой контакт в разъеме клапана EVAP. Исправьте разъем в отношении качества контактов, смотрите ru-RU0900c8af80be4147#KC01111298, а также контактного сопротивления и окисления , смотрите ru-RU0900c8af80be4147#KC01106363.\nru-RU0900c8af80630c67#KC02333698\nПроверьте провод между разъемом 2 клапана EVAP и ECM #A39 на предмет короткого замыкания на землю, смотрите ru-RU0900c8af80be4147#KC01106352.\nru-RU0900c8af80630c67#KC02333699\nЕсли омметр показывает бесконечно большое сопротивление:\nПроверьте разъем ECM, смотрите ru-RU0900c8af80630c67#KC02333700.\nПричиной вывода кода DTC является плохой контакт в разъеме клапана EVAP.\nИсправьте разъем в отношении качества контактов, смотрите ru-RU0900c8af80854dc2#KC01106832, а также контактного сопротивления и окисления , смотрите ru-RU0900c8af80be4147#KC01106363.\nИсправьте разъем ECM в отношении контактного сопротивления и окисления, смотрите ru-RU0900c8af80be4147#KC01106363.\nru-RU0900c8af80630c67#KC02333701\nПроверьте провод между разъемом 2 клапана EVAP и ECM #A39 на предмет размыкания, смотрите ru-RU0900c8af80be4147#KC01106360.\nru-RU0900c8af80630c67#KC02333702\nПропадающая неисправность","description_markdown":"# Ошибочный сигнал\n\nОшибочный сигнал\n\n5-3-1 Группа A силового каскада\n\nПроверка форсунок\n\nЗапустите DTM 3.\n\n> ⚠️ Последовательность DTM автоматически запустит вентилятор охлаждения двигателя.\n\nПоследовательность DTM автоматически запустит вентилятор охлаждения двигателя.\n\nО последовательности DTM 3 смотрите ru-RU0900c8af8042110e#KC01463050.\n\nДля нормальной работы DTM 3 должны быть подсоединены три форсунки. Таким образом тест может выполняться несколько раз для разных форсунок.\n\nПроверьте, хорошо ли работают форсунки.\n\n## Вопрос\n\nНормально ли работают форсунки?\n\nru-RU0900c8af80630c67#KC02333690\n\nru-RU0900c8af80630c67#KC02333678\n\nПроверка подачи питания на форсунки\n\nВыключите зажигание.\n\nОтключите соответствующую форсунку.\n\nВключите зажигание.\n\nПодсоедините вольтметр между разъемом 1 форсунки и землей.\n\n## Вопрос\n\nВольтметр должен показывать напряжение аккумулятора.\n\nru-RU0900c8af80630c67#KC02333680\n\nПроверьте провод между разъемом 3 главного реле (2/32) и разъемом 1 форсунки на предмет размыкания, смотрите ru-RU0900c8af80be4147#KC01106360.\n\nru-RU0900c8af80630c67#KC02333679\n\nПроверка на размыкание\n\n## Вопрос\n\nПосле устранения неисправности выберите \"Continue\" (Продолжить).\n\nПроверьте форсунку\n\nОтсоедините форсунку.\n\nПодсоедините омметр между разъемами 1 и 2 форсунки.\n\n## Вопрос\n\nОмметр должен показывать приблизительно 14,5 Ω при +20°C .\n\nru-RU0900c8af80630c67#KC02333682\n\nПроверьте работу с новой форсункой.\n\nru-RU0900c8af80630c67#KC02333681\n\nЗамена компонента\n\n## Вопрос\n\nПосле устранения неисправности выберите \"Continue\" (Продолжить).\n\nПроверка сигнального провода\n\nПодсоедините вольтметр между разъемом 2 форсунки и землей.\n\n## Вопрос\n\nВольтметр должен показывать приблизительно 0 В.\n\nru-RU0900c8af80630c67#KC02333684\n\nПроверьте провод между разъемом 2 форсунки и ECM #A10, #A38, #A24, #A23 или #A9 (в зависимости от того, какая именно форсунка не работает) на предмет короткого замыкания на источник питания, смотрите ru-RU0900c8af80be4147#KC01106854.\n\nru-RU0900c8af80630c67#KC02333683\n\nПроверка на короткое замыкание\n\n## Вопрос\n\nПосле устранения неисправности выберите \"Continue\" (Продолжить).\n\nПроверка сопротивления между сигнальным проводом и землей\n\nПодождите примерно 150 сек.\n\nПодсоедините омметр между разъемом 2 форсунки и землей.\n\n## Вопрос\n\nОмметр должен показывать 25 - 40 кОм;.\n\nПричиной вывода кода DTC является плохой контакт в разъеме форсунки. Исправьте разъем в отношении качества контакта, смотрите ru-RU0900c8af80be4147#KC01111298, а также контактного сопротивления и окисления, смотрите ru-RU0900c8af80be4147#KC01106363.\n\nru-RU0900c8af80630c67#KC02333685\n\nПроверьте провод между разъемом 2 форсунки и ECM #A10, #A38, #A24, #A23 или #A9 (в зависимости от того, какая именно форсунка не работает) на предмет короткого замыкания на землю, смотрите ru-RU0900c8af80be4147#KC01106352.\n\nru-RU0900c8af80630c67#KC02333686\n\nru-RU0900c8af80630c67#KC02333687\n\nИнформация для поиска неисправностей\n\nПричиной вывода кода DTC является плохой контакт в разъеме форсунки.\n\nИсправьте разъем в отношении качества контакта, смотрите ru-RU0900c8af80854dc2#KC01106832 , а также контактного сопротивления и окисления , смотрите ru-RU0900c8af80be4147#KC01106363.\n\n## Вопрос\n\nПосле устранения неисправности выберите \"Continue\" (Продолжить).\n\n## Вопрос\n\nПосле устранения неисправности выберите \"Continue\" (Продолжить).\n\nПроверка разъема ECM\n\nИсправьте разъем ECM (сопротивление и окисление разъема), смотрите ru-RU0900c8af80be4147#KC01106363.\n\nБлок ECM подсоединен.\n\n## Вопрос\n\nОмметр должен показывать 25 - 40 кОм;.\n\nПричиной вывода кода DTC является плохой контакт в разъеме ECM.\n\nru-RU0900c8af80630c67#KC02333688\n\nПроверьте провод между разъемом 2 форсунки и ECM #A10, #A38, #A24, #A23 или #A9 (в зависимости от того, какая именно форсунка не работает) на предмет размыкания, смотрите ru-RU0900c8af80be4147#KC01106360.\n\nru-RU0900c8af80630c67#KC02333689\n\n## Вопрос\n\nВыберите \"Continue\" (Продолжить).\n\n## Вопрос\n\nПосле устранения неисправности выберите \"Continue\" (Продолжить).\n\nПроверка клапана EVAP\n\n> ⚠️ Последовательность DTM автоматически запустит вентилятор охлаждения двигателя.\n\nПроверьте, нормально ли работает клапан EVAP.\n\n## Вопрос\n\nНормально ли работает клапан EVAP?\n\nru-RU0900c8af80630c67#KC02333703\n\nru-RU0900c8af80630c67#KC02333691\n\nПроверка напряжения на клапане EVAP\n\nДля того, чтобы добраться до клапана EVAP, необходимо отсоединить следующие компоненты:\n\nКлапан от кронштейна.\n\nЗвукоизоляцию от клапана.\n\nПосле обнаружении неисправности установите клапан, шланги и звукоизоляцию на место при помощи плоскогубцев 981 4215, следует также установить новый хомут шланга.\n\nОтсоедините клапан EVAP.\n\nПодсоедините вольтметр между разъемом 1 клапана EVAP и землей.\n\n## Вопрос\n\nВольтметр должен показывать напряжение аккумулятора.\n\nru-RU0900c8af80630c67#KC02333693\n\nПроверьте провод между разъемом 1 клапана EVAP и главным реле (2/32) на предмет размыкания, смотрите ru-RU0900c8af80be4147#KC01106360.\n\nru-RU0900c8af80630c67#KC02333692\n\n## Вопрос\n\nПосле устранения неисправности выберите \"Continue\" (Продолжить).\n\nКлапан EVAP отсоединен.\n\nПодсоедините омметр между разъемами 1 и 2 клапана EVAP.\n\n## Вопрос\n\nОмметр должен показывать приблизительно 26 Ω при +20°C .\n\nru-RU0900c8af80630c67#KC02333695\n\nПроверьте работу с новым клапаном EVAP.\n\nru-RU0900c8af80630c67#KC02333694\n\n## Вопрос\n\nПосле устранения неисправности выберите \"Continue\" (Продолжить).\n\nПодсоедините вольтметр между разъемом 2 клапана EVAP и землей.\n\n## Вопрос\n\nВольтметр должен показывать приблизительно 0 В.\n\nru-RU0900c8af80630c67#KC02333697\n\nПроверьте провод между разъемом 2 клапана EVAP и ECM #A39 на предмет короткого замыкания на источник питания, смотрите ru-RU0900c8af80be4147#KC01106854.\n\nru-RU0900c8af80630c67#KC02333696\n\n## Вопрос\n\nПосле устранения неисправности выберите \"Continue\" (Продолжить).\n\nПодсоедините омметр между разъемом 2 клапана EVAP и землей.\n\n## Вопрос\n\nОмметр должен показывать 25 - 40 кОм;.\n\nПричиной вывода кода DTC является плохой контакт в разъеме клапана EVAP. Исправьте разъем в отношении качества контактов, смотрите ru-RU0900c8af80be4147#KC01111298, а также контактного сопротивления и окисления , смотрите ru-RU0900c8af80be4147#KC01106363.\n\nru-RU0900c8af80630c67#KC02333698\n\nПроверьте провод между разъемом 2 клапана EVAP и ECM #A39 на предмет короткого замыкания на землю, смотрите ru-RU0900c8af80be4147#KC01106352.\n\nru-RU0900c8af80630c67#KC02333699\n\nПроверьте разъем ECM, смотрите ru-RU0900c8af80630c67#KC02333700.\n\nПричиной вывода кода DTC является плохой контакт в разъеме клапана EVAP.\n\nИсправьте разъем в отношении качества контактов, смотрите ru-RU0900c8af80854dc2#KC01106832, а также контактного сопротивления и окисления , смотрите ru-RU0900c8af80be4147#KC01106363.\n\n## Вопрос\n\nПосле устранения неисправности выберите \"Continue\" (Продолжить).\n\n## Вопрос\n\nПосле устранения неисправности выберите \"Continue\" (Продолжить).\n\nИсправьте разъем ECM в отношении контактного сопротивления и окисления, смотрите ru-RU0900c8af80be4147#KC01106363.\n\n## Вопрос\n\nОмметр должен показывать 25 - 40 кОм;.\n\nru-RU0900c8af80630c67#KC02333701\n\nПроверьте провод между разъемом 2 клапана EVAP и ECM #A39 на предмет размыкания, смотрите ru-RU0900c8af80be4147#KC01106360.\n\nru-RU0900c8af80630c67#KC02333702\n\n## Вопрос\n\nВыберите \"Continue\" (Продолжить).\n\n## Вопрос\n\nПосле устранения неисправности выберите \"Continue\" (Продолжить).\n\nПропадающая неисправность","xml_size":5410}