{"id":-2146683480,"chronicle_id":"0900c8af800c35a8","project_document_id":"0800c8af800c35a9","fk_document_type":4,"document_type":"diag:servinfosub","vcc_number":"VCC-088157-1","nevis_id":"0900c8af800c35a8","path":"VCC-088157-1\\0900c8af800c35a8_ru-RU.xml","title":"Ошибочный сигнал","xml_filename":"0900c8af800c35a8_ru-RU.xml","description_raw":"<?xml version=\"1.0\" encoding=\"utf-8\"?><servinfosub docno=\"VCC-088157\" id=\"KC01106390\" xml:lang=\"ru-RU\" IE-ID=\"ru-RU0900c8af800c35a8\"><title><phrase category=\"\" id=\"KC06919691\" phrase-urn=\"urn:x-nevis:phrase:0800c8af819feddf\">Ошибочный сигнал</phrase></title><diagnostic j2008use=\"1\" paperuse=\"1\" screenuse=\"1\" type=\"test\"><testgrp id=\"KC01153669\" j2008use=\"1\" paperuse=\"1\" resumable=\"1\" screenuse=\"1\" testgrp-id=\"node5\" x=\"120\" y=\"120\" IE-ID=\"ru-RU0900c8af800c35a8_KC01153669\"><title><phrase category=\"\" id=\"KC06919692\" phrase-urn=\"urn:x-nevis:phrase:0800c8af819fede0\">Запрос</phrase></title><subcalloutnode><diagcallout><xref><ref id=\"KC06919693\"><href title=\"VCC-111955-1, Вопрос\">ru-RU0900c8af80071b39#KC01126232</href></ref></xref></diagcallout><rescall-grp><result comp=\"string\" highlight=\"0\" op=\"eq\" return=\"STC\"></result><calloutaction><ptxt><xref><ref id=\"KC06919694\"><href title=\"Проверка разъемов и кабелей\">ru-RU0900c8af800c35a8#KC01153670</href></ref></xref></ptxt></calloutaction></rescall-grp><rescall-grp><result comp=\"string\" highlight=\"0\" op=\"eq\" return=\"DSTC\"></result><calloutaction><ptxt><xref><ref id=\"KC06919695\"><href title=\"DSTC\">ru-RU0900c8af800c35a8#KC01153673</href></ref></xref></ptxt></calloutaction></rescall-grp></subcalloutnode></testgrp><testgrp id=\"KC01153670\" j2008use=\"1\" paperuse=\"1\" resumable=\"1\" screenuse=\"1\" testgrp-id=\"node1\" x=\"120\" y=\"240\"><title><phrase category=\"\" id=\"KC06919696\" phrase-urn=\"urn:x-nevis:phrase:0800c8af819fede2\">Проверка разъемов и кабелей</phrase></title><node><test1><test2><para><ptxt><phrase category=\"\" id=\"KC06919697\" phrase-urn=\"urn:x-nevis:phrase:0800c8af819fede3\">Проверьте разъемы соответствующего датчика колеса и модуля управления ABS на наличие контактного сопротивления и окисления согласно <xref><ref id=\"KC06919698\"><href title=\"VCC-018853-1, Проверка проводки и выводов. Постоянные неисправности\">ru-RU0900c8af80be4147#KC01106363</href></ref></xref>.</phrase></ptxt></para><para><ptxt><phrase category=\"\" id=\"KC06919699\" phrase-urn=\"urn:x-nevis:phrase:0800c8af819fede5\">Проверьте, не повреждены ли разъемы и изоляция проводки.</phrase></ptxt></para><para><ptxt><phrase category=\"\" id=\"KC06919700\" phrase-urn=\"urn:x-nevis:phrase:0800c8af819fede6\">Убедитесь, что кабели датчика колеса не расположены слишком близко к источникам помех. </phrase></ptxt></para><ptxt><phrase category=\"\" id=\"KC06919701\" phrase-urn=\"urn:x-nevis:phrase:0800c8af819fede7\">Выполните необходимый ремонт.</phrase></ptxt><list1 enumtype=\"d\" type=\"unordered\"><title><phrase category=\"\" id=\"KC06919702\" phrase-urn=\"urn:x-nevis:phrase:0800c8af819fede9\">Другая информация</phrase></title><item><ptxt><phrase category=\"\" id=\"KC06919703\" phrase-urn=\"urn:x-nevis:phrase:0800c8af819fedea\">Чтобы подсоединить измерительный блок, см. <xref><ref id=\"KC06919704\"><href title=\"VCC-095843-1, Подсоединение измерительного блока ABS\">ru-RU0900c8af80876041#KC01115388</href></ref></xref></phrase></ptxt></item><item><ptxt><phrase category=\"\" id=\"KC06919705\" phrase-urn=\"urn:x-nevis:phrase:0800c8af819fedec\">Чтобы отсоединить разъем модуля управления, см. <xref><ref id=\"KC06919706\"><href title=\"VCC-088295-1, Модуль управления (ABS), замена\">ru-RU0900c8af808638b9#KC01126256</href></ref></xref></phrase></ptxt></item><item><ptxt><phrase category=\"\" id=\"KC06919707\" phrase-urn=\"urn:x-nevis:phrase:0800c8af819feded\">Чтобы проверить и заменить датчики колес, см. <xref><ref id=\"KC06919708\"><href title=\"VCC-088294-1, Датчики колес, задние, замена\">ru-RU0900c8af800c3ad9#KC01131694</href></ref></xref></phrase></ptxt></item><item><ptxt><phrase category=\"\" id=\"KC06919709\" phrase-urn=\"urn:x-nevis:phrase:0800c8af819fedee\">Чтобы получить информацию о сигналах, см. <xref><ref id=\"KC06919710\"><href title=\"VCC-095400-1, Параметры сигналов, модуль управления ABS\">ru-RU0900c8af80875f3e#KC01121060</href></ref></xref>. </phrase></ptxt></item></list1></test2></test1><question>Была ли обнаружена неисправность?</question><resact-grp><result button=\"yes\" comp=\"button\" highlight=\"0\"></result><action j2008use=\"1\" paperuse=\"1\" screenuse=\"1\"><ptxt><xref><ref id=\"KC06919711\"><href title=\"Проверка\">ru-RU0900c8af800c35a8#KC01153671</href></ref></xref></ptxt></action></resact-grp><resact-grp><result button=\"no\" comp=\"button\" highlight=\"0\"></result><action j2008use=\"1\" paperuse=\"1\" screenuse=\"1\"><return value=\"FAULT NOT FOUND\"></return></action></resact-grp></node></testgrp><testgrp id=\"KC01153671\" j2008use=\"1\" paperuse=\"1\" resumable=\"1\" screenuse=\"1\" testgrp-id=\"veri2\" x=\"280\" y=\"240\"><title><phrase category=\"\" id=\"KC06919712\" phrase-urn=\"urn:x-nevis:phrase:0800c8af819fedf0\">Проверка</phrase></title><subcalloutnode><diagcallout><xref><ref id=\"KC06919713\"><href title=\"VCC-103805-1, Верификация\">ru-RU0900c8af80071249#KC01153696</href></ref></xref></diagcallout><rescall-grp><result comp=\"string\" highlight=\"0\" op=\"eq\" return=\"VERIFIED\"></result><calloutaction><return value=\"FAULT FOUND\"></return></calloutaction></rescall-grp><rescall-grp><result comp=\"string\" highlight=\"0\" op=\"eq\" return=\"VERIFICATION FAILED\"></result><calloutaction><ptxt><xref><ref id=\"KC06919714\"><href title=\"Информация по поиску неисправности\">ru-RU0900c8af800c35a8#KC01153672</href></ref></xref></ptxt></calloutaction></rescall-grp><rescall-grp><result comp=\"string\" highlight=\"0\" op=\"eq\" return=\"PAPER\"></result><calloutaction><return value=\"FAULT NOT FOUND\"></return></calloutaction></rescall-grp></subcalloutnode></testgrp><testgrp id=\"KC01153672\" j2008use=\"1\" paperuse=\"0\" resumable=\"1\" screenuse=\"1\" testgrp-id=\"info1\" x=\"480\" y=\"240\"><title><phrase category=\"\" id=\"KC06919715\" phrase-urn=\"urn:x-nevis:phrase:0800c8af819fedf1\">Информация по поиску неисправности</phrase></title><subcalloutnode><diagcallout><xref><ref id=\"KC06919716\"><href title=\"VCC-002087-1, Информация\">ru-RU0900c8af8006ff94#KC01106273</href></ref></xref></diagcallout><rescall-grp><result comp=\"string\" highlight=\"0\" op=\"eq\" return=\"FAULTTRACING FAILED\"></result><calloutaction><return value=\"FAULTTRACING FAILED\"></return></calloutaction></rescall-grp><rescall-grp><result comp=\"string\" highlight=\"0\" op=\"eq\" return=\"NEW TRY\"></result><calloutaction><ptxt><xref><ref id=\"KC06919717\"><href title=\"Проверка разъемов и кабелей\">ru-RU0900c8af800c35a8#KC01153670</href></ref></xref></ptxt></calloutaction></rescall-grp></subcalloutnode></testgrp><testgrp id=\"KC01153673\" j2008use=\"1\" paperuse=\"1\" resumable=\"1\" screenuse=\"1\" testgrp-id=\"node6\" x=\"320\" y=\"120\"><title><phrase category=\"\" id=\"KC06919718\" phrase-urn=\"urn:x-nevis:phrase:0800c8af819fedf3\">DSTC</phrase></title><subcalloutnode><diagcallout><xref><ref id=\"KC06919719\"><href title=\"VCC-111984-1, Сигнал ошибочный\">ru-RU0900c8af8011a4a3#KC01153703</href></ref></xref></diagcallout><rescall-grp><result comp=\"string\" highlight=\"0\" op=\"eq\" return=\"FAULT NOT FOUND\"></result><calloutaction><return value=\"FAULT NOT FOUND\"></return></calloutaction></rescall-grp><rescall-grp><result comp=\"string\" highlight=\"0\" op=\"eq\" return=\"FAULT FOUND\"></result><calloutaction><return value=\"FAULT FOUND\"></return></calloutaction></rescall-grp><rescall-grp><result comp=\"string\" highlight=\"0\" op=\"eq\" return=\"FAULTTRACING FAILED\"></result><calloutaction><return value=\"FAULTTRACING FAILED\"></return></calloutaction></rescall-grp></subcalloutnode></testgrp></diagnostic></servinfosub>","description_plain":"Ошибочный сигнал\nЗапрос\nru-RU0900c8af800c35a8#KC01153670\nru-RU0900c8af800c35a8#KC01153673\nПроверка разъемов и кабелей\nПроверьте разъемы соответствующего датчика колеса и модуля управления ABS на наличие контактного сопротивления и окисления согласно ru-RU0900c8af80be4147#KC01106363.\nПроверьте, не повреждены ли разъемы и изоляция проводки.\nУбедитесь, что кабели датчика колеса не расположены слишком близко к источникам помех.\nВыполните необходимый ремонт.\nДругая информация\nЧтобы подсоединить измерительный блок, см. ru-RU0900c8af80876041#KC01115388\nЧтобы отсоединить разъем модуля управления, см. ru-RU0900c8af808638b9#KC01126256\nЧтобы проверить и заменить датчики колес, см. ru-RU0900c8af800c3ad9#KC01131694\nЧтобы получить информацию о сигналах, см. ru-RU0900c8af80875f3e#KC01121060.\nБыла ли обнаружена неисправность?\nru-RU0900c8af800c35a8#KC01153671\nПроверка\nru-RU0900c8af800c35a8#KC01153672\nИнформация по поиску неисправности\nDSTC","description_markdown":"# Ошибочный сигнал\n\nОшибочный сигнал\n\nЗапрос\n\nru-RU0900c8af800c35a8#KC01153670\n\nru-RU0900c8af800c35a8#KC01153673\n\nПроверка разъемов и кабелей\n\nПроверьте разъемы соответствующего датчика колеса и модуля управления ABS на наличие контактного сопротивления и окисления согласно ru-RU0900c8af80be4147#KC01106363.\n\nПроверьте, не повреждены ли разъемы и изоляция проводки.\n\nУбедитесь, что кабели датчика колеса не расположены слишком близко к источникам помех.\n\nВыполните необходимый ремонт.\n\nДругая информация\n\nЧтобы подсоединить измерительный блок, см. ru-RU0900c8af80876041#KC01115388\n\nЧтобы отсоединить разъем модуля управления, см. ru-RU0900c8af808638b9#KC01126256\n\nЧтобы проверить и заменить датчики колес, см. ru-RU0900c8af800c3ad9#KC01131694\n\nЧтобы получить информацию о сигналах, см. ru-RU0900c8af80875f3e#KC01121060.\n\n## Вопрос\n\nБыла ли обнаружена неисправность?\n\nru-RU0900c8af800c35a8#KC01153671\n\nПроверка\n\nru-RU0900c8af800c35a8#KC01153672\n\nИнформация по поиску неисправности\n\nDSTC","xml_size":1943}