Checking atmospheric pressure sensor signal
Checking atmospheric pressure sensor signal
Checking atmospheric pressure sensor function
Ignition on.
Read off the atmospheric pressure sensor value.
The atmospheric pressure sensor value should be 81-101 kPa.
Вопрос
Is the value correct?
ru-RU0900c8af8104d419#KC01402305
ru-RU0900c8af80920c30#KC02495982
Checking connectors
Ignition off.
Check control module and atmospheric pressure sensor connectors for contact resistance and oxidation and remedy according toru-RU0900c8af80be4147#KC01106363.
Other information:
To access the control module/connect the breakout box, see ru-RU0900c8af8049e25d#KC01395794.
To access/replace volume air flow (VAF) sensor, see ru-RU0900c8af804a08ea#KC01395797.
Вопрос
Was this value OK?
ru-RU0900c8af80920c30#KC02495983
Replacing component
Replace volume air flow (VAF) sensor according to ru-RU0900c8af804a08ea#KC01395797.
Вопрос
Select “Continue”.
ru-RU0900c8af80920c30#KC02495984
Verification
ru-RU0900c8af80920c30#KC02495985
Fault-tracing information
ru-RU0900c8af80920c30#KC02495981
Plain text
Checking atmospheric pressure sensor signal Checking atmospheric pressure sensor function Ignition on. Read off the atmospheric pressure sensor value. The atmospheric pressure sensor value should be 81-101 kPa. Is the value correct? ru-RU0900c8af8104d419#KC01402305 ru-RU0900c8af80920c30#KC02495982 Checking connectors Ignition off. Check control module and atmospheric pressure sensor connectors for contact resistance and oxidation and remedy according toru-RU0900c8af80be4147#KC01106363. Other information: To access the control module/connect the breakout box, see ru-RU0900c8af8049e25d#KC01395794. To access/replace volume air flow (VAF) sensor, see ru-RU0900c8af804a08ea#KC01395797. Was this value OK? ru-RU0900c8af80920c30#KC02495983 Replacing component Replace volume air flow (VAF) sensor according to ru-RU0900c8af804a08ea#KC01395797. Select "Continue". ru-RU0900c8af80920c30#KC02495984 Verification ru-RU0900c8af80920c30#KC02495985 Fault-tracing information ru-RU0900c8af80920c30#KC02495981
Raw XML
<?xml version="1.0" encoding="utf-8"?><servinfosub docno="VCC-108573" id="KC02495980" xml:lang="ru-RU" IE-ID="ru-RU0900c8af80920c30"><title><phrase category="" id="KC07779243" phrase-urn="urn:x-nevis:phrase:0800c8af81bc40dd">Checking atmospheric pressure sensor signal</phrase></title><diagnostic type="test"><testgrp id="KC02495981" j2008use="1" paperuse="1" resumable="1" screenuse="1" testgrp-id="NODE1" x="880" y="160" IE-ID="ru-RU0900c8af80920c30_KC02495981"><title><phrase category="" id="KC07779244" phrase-urn="urn:x-nevis:phrase:0800c8af81bc40de">Checking atmospheric pressure sensor function</phrase></title><node><test1><diaglist><dgraphic><dgraphic1><graphic id="KC07779245"><href title="A3000040">0900c8af80054d55_0_0.gif</href></graphic></dgraphic1></dgraphic><ditem><ptxt><phrase category="" id="KC07779246" phrase-urn="urn:x-nevis:phrase:0800c8af81bc40df">Ignition on.</phrase></ptxt></ditem></diaglist><test2><para><ptxt><phrase category="" id="KC07779247" phrase-urn="urn:x-nevis:phrase:0800c8af81bc40e0">Read off the atmospheric pressure sensor value.</phrase></ptxt></para><para><ptxt><phrase category="" id="KC07779248" phrase-urn="urn:x-nevis:phrase:0800c8af81bc40e1">The atmospheric pressure sensor value should be 81-101 kPa.</phrase></ptxt></para><diaglist><dgraphic><dgraphic2><graphic id="KC07779249"><href title="A0801035">0900c8af800547da_0_0.gif</href></graphic><smarttool active="press" id="KC07779250" toolname="XF13A506"><href title="XF13A506, Lufttryck">0800c8af804caa07</href></smarttool></dgraphic2></dgraphic><ditem><ditemtext><ptxt><phrase category="" id="KC07779251" phrase-urn="urn:x-nevis:phrase:0800c8af81bc40e2"></phrase></ptxt></ditemtext></ditem><ditem><ditemtext><ptxt><phrase category="" id="KC07779252" phrase-urn="urn:x-nevis:phrase:0800c8af81bc40e3"></phrase></ptxt></ditemtext></ditem></diaglist></test2></test1><question>Is the value correct?</question><resact-grp><result button="ok" comp="button" highlight="0"></result><action j2008use="0" paperuse="1" screenuse="0"><ptxt><xref><ref id="KC07779253"><href title="Invalid virgin link from Nevis">ru-RU0900c8af8104d419#KC01402305</href></ref></xref></ptxt></action><action j2008use="1" paperuse="0" screenuse="1"><return value="FAULT NOT FOUND"></return></action></resact-grp><resact-grp><result button="notok" comp="button" highlight="0"></result><action j2008use="1" paperuse="1" screenuse="1"><ptxt><xref><ref id="KC07779254"><href title="Checking connectors">ru-RU0900c8af80920c30#KC02495982</href></ref></xref></ptxt></action></resact-grp></node></testgrp><testgrp id="KC02495982" j2008use="1" paperuse="1" resumable="1" screenuse="1" testgrp-id="NODE2" x="880" y="160"><title><phrase category="" id="KC07779255" phrase-urn="urn:x-nevis:phrase:0800c8af81bc40e4">Checking connectors</phrase></title><node><test1><diaglist><dgraphic><dgraphic1><graphic id="KC07779256"><href title="A3000040">0900c8af80054d55_0_0.gif</href></graphic></dgraphic1></dgraphic><ditem><ptxt><phrase category="" id="KC07779257" phrase-urn="urn:x-nevis:phrase:0800c8af81bc40e5">Ignition off.</phrase></ptxt></ditem><ditem><ptxt><phrase category="" id="KC07779258" phrase-urn="urn:x-nevis:phrase:0800c8af81bc40e6">Check control module and atmospheric pressure sensor connectors for contact resistance and oxidation and remedy according to<xref><ref id="KC07779259"><href title="VCC-018853-1, Проверка проводки и выводов. Постоянные неисправности">ru-RU0900c8af80be4147#KC01106363</href></ref></xref>.</phrase></ptxt></ditem><ditem><ptxt><phrase category="" id="KC07779260" phrase-urn="urn:x-nevis:phrase:0800c8af81bc40e7">Ignition on.</phrase></ptxt></ditem></diaglist><test2><para><ptxt><phrase category="" id="KC07779261" phrase-urn="urn:x-nevis:phrase:0800c8af81bc40e8">Read off the atmospheric pressure sensor value.</phrase></ptxt></para><para><ptxt><phrase category="" id="KC07779262" phrase-urn="urn:x-nevis:phrase:0800c8af81bc40e9">The atmospheric pressure sensor value should be 81-101 kPa.</phrase></ptxt></para><list1 enumtype="d" type="unordered"><title><phrase category="" id="KC07779263" phrase-urn="urn:x-nevis:phrase:0800c8af81bc40ea">Other information:</phrase></title><item><ptxt><phrase category="" id="KC07779264" phrase-urn="urn:x-nevis:phrase:0800c8af81bc40eb">To access the control module/connect the breakout box, see <xref><ref id="KC07779265"><href title="VCC-087210-1, Подсоединение измерительного блока">ru-RU0900c8af8049e25d#KC01395794</href></ref></xref>.</phrase></ptxt></item><item><ptxt><phrase category="" id="KC07779266" phrase-urn="urn:x-nevis:phrase:0800c8af81bc40ec">To access/replace volume air flow (VAF) sensor, see <xref><ref id="KC07779267"><href title="VCC-089000-1, Замена датчика воздушного потока">ru-RU0900c8af804a08ea#KC01395797</href></ref></xref>.</phrase></ptxt></item></list1><diaglist><dgraphic><dgraphic2><graphic id="KC07779268"><href title="A0801035">0900c8af800547da_0_0.gif</href></graphic><smarttool active="press" id="KC07779269" toolname="XF13A506"><href title="XF13A506, Lufttryck">0800c8af804caa07</href></smarttool></dgraphic2></dgraphic><ditem><ditemtext><ptxt><phrase category="" id="KC07779270" phrase-urn="urn:x-nevis:phrase:0800c8af81bc40ed"></phrase></ptxt></ditemtext></ditem><ditem><ditemtext><ptxt><phrase category="" id="KC07779271" phrase-urn="urn:x-nevis:phrase:0800c8af81bc40ee"></phrase></ptxt></ditemtext></ditem></diaglist></test2></test1><question>Was this value OK?</question><resact-grp><result button="ok" comp="button" highlight="0"></result><action j2008use="1" paperuse="1" screenuse="1"><return value="FAULT FOUND"></return></action></resact-grp><resact-grp><result button="notok" comp="button" highlight="0"></result><action j2008use="1" paperuse="1" screenuse="1"><ptxt><xref><ref id="KC07779272"><href title="Replacing component">ru-RU0900c8af80920c30#KC02495983</href></ref></xref></ptxt></action></resact-grp></node></testgrp><testgrp id="KC02495983" j2008use="1" paperuse="1" resumable="1" screenuse="1" testgrp-id="NODE3" x="880" y="160"><title><phrase category="" id="KC07779273" phrase-urn="urn:x-nevis:phrase:0800c8af81bc40ef">Replacing component</phrase></title><node><test1><test2><ptxt><phrase category="" id="KC07779274" phrase-urn="urn:x-nevis:phrase:0800c8af81bc40f0">Replace volume air flow (VAF) sensor according to <xref><ref id="KC07779275"><href title="VCC-089000-1, Замена датчика воздушного потока">ru-RU0900c8af804a08ea#KC01395797</href></ref></xref>.</phrase></ptxt></test2></test1><question>Select "Continue".</question><resact-grp><result button="cont" comp="button" highlight="0"></result><action j2008use="1" paperuse="1" screenuse="1"><ptxt><xref><ref id="KC07779276"><href title="Verification">ru-RU0900c8af80920c30#KC02495984</href></ref></xref></ptxt></action></resact-grp></node></testgrp><testgrp id="KC02495984" j2008use="1" paperuse="1" resumable="1" screenuse="1" testgrp-id="VERIA" x="360" y="160"><title><phrase category="" id="KC07779277" phrase-urn="urn:x-nevis:phrase:0800c8af81bc40f1">Verification</phrase></title><subcalloutnode><diagcallout><xref><ref id="KC07779278"><href title="VCC-108574-1, Verification">ru-RU0900c8af808ecc0a#KC02493777</href></ref></xref></diagcallout><rescall-grp><result comp="string" highlight="0" op="eq" return="VERIFIED"></result><calloutaction><return value="FAULT FOUND"></return></calloutaction></rescall-grp><rescall-grp><result comp="string" highlight="0" op="eq" return="VERIFICATION FAILED"></result><calloutaction><ptxt><xref><ref id="KC07779279"><href title="Fault-tracing information">ru-RU0900c8af80920c30#KC02495985</href></ref></xref></ptxt></calloutaction></rescall-grp><rescall-grp><result comp="string" highlight="0" op="eq" return="PAPER"></result><calloutaction><return value="FAULT NOT FOUND"></return></calloutaction></rescall-grp></subcalloutnode></testgrp><testgrp id="KC02495985" j2008use="1" paperuse="0" resumable="1" screenuse="1" testgrp-id="INFO1" x="600" y="160"><title><phrase category="" id="KC07779280" phrase-urn="urn:x-nevis:phrase:0800c8af81bc40f2">Fault-tracing information</phrase></title><subcalloutnode><diagcallout><xref><ref id="KC07779281"><href title="VCC-002087-1, Информация">ru-RU0900c8af8006ff94#KC01106273</href></ref></xref></diagcallout><rescall-grp><result comp="string" highlight="0" op="eq" return="FAULTTRACING FAILED"></result><calloutaction><return value="FAULTTRACING FAILED"></return></calloutaction></rescall-grp><rescall-grp><result comp="string" highlight="0" op="eq" return="NEW TRY"></result><calloutaction><ptxt><xref><ref id="KC07779282"><href title="Checking atmospheric pressure sensor function">ru-RU0900c8af80920c30#KC02495981</href></ref></xref></ptxt></calloutaction></rescall-grp></subcalloutnode></testgrp></diagnostic></servinfosub>